POWER MODULE REPLACEMENT

MAINTENANCE

POWER MODULE REPLACEMENT

1)Remove the exterior brick panels.

2)Remove the glass door.

a.Release the 2 door latches on the left and right side at the top of the fi rebox.

Latch Location

Latch

4)Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket (located directly above the heat shield).

Bracket

Heat

Shield

8)Remove the 3 connectors from the circuit board.

9)Remove the circuit board from the support bracket by turning it around and pushing the plastic pins with a plier.

MAINTENANCE

b.Swingthedooroutfromthetopandrelease the hinges on the left and right side of the door by lifting them up.

Hinge

Door

3)Loosen the 2 screws that hold the left side heat shield in place.

Heat

Shield

5)Unplug the power source.

6 ) Remove the top screw and loosen the bottom screw that hold the power module in place.

Power

Bracket Module

7)Remove the power module cover by removing the 2 screws, one on each side.

Power Module

Power Module with Cover Removed

Circuit Board Removed

10)Replace the circuit board.

11)Reverse steps to re-install.