INSTALLATION
INSTALLATION
AERATION
ADJUSTMENT
The burner aeration is factory set but may need | Minimum Air Shutter Opening: | CAUTION: Carbon will be produced if air shutter | ||
adjusting due to either the local gas supply or | NG | Front Burner | 1/4" | is tightly closed. |
altitude. Open the air shutter for a blue fl ame or |
| |||
close for a more yellow fl ame. |
| Rear Burner | 1/8" | Note: Any damage due to carboning |
| LP | Front Burner | 5/16" | resulting from improperly setting |
In order to adjust the aeration, the logs, grate | the aeration controls is NOT covered | |||
and burners will need to be removed to be able |
| Rear Burner | 1/4" | under warranty. |
to access the shutters. |
|
|
|
|
A receptacle is provided on the left hand side of the unit. 120 Volt AC power must be wired to the receptacle and the control module plugged in for the unit to operate fully. The front and rear burners will operate on low, when the unit is running on battery
WIRING DIAGRAM
(Do not cut the ground terminal off under any circumstances.)
Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
38 | Regency® L676 Direct Vent Gas Fireplace |