INSTALLATION

INSTALLATION

AERATION

ADJUSTMENT

The burner aeration is factory set but may need

Minimum Air Shutter Opening:

CAUTION: Carbon will be produced if air shutter

adjusting due to either the local gas supply or

NG

Front Burner

1/4"

is tightly closed.

altitude. Open the air shutter for a blue fl ame or

 

close for a more yellow fl ame.

 

Rear Burner

1/8"

Note: Any damage due to carboning

 

LP

Front Burner

5/16"

resulting from improperly setting

In order to adjust the aeration, the logs, grate

the aeration controls is NOT covered

and burners will need to be removed to be able

 

Rear Burner

1/4"

under warranty.

to access the shutters.

 

 

 

 

A receptacle is provided on the left hand side of the unit. 120 Volt AC power must be wired to the receptacle and the control module plugged in for the unit to operate fully. The front and rear burners will operate on low, when the unit is running on battery back-up.

WIRING DIAGRAM

(Do not cut the ground terminal off under any circumstances.)

Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.