Regency L676 Installation, CONVERSION KIT #521-969FROM NG TO LP, LP Conversion Kit Contains

Models: L676

1 56
Download 56 pages 33.98 Kb
Page 28
Image 28
CONVERSION KIT #521-969 FROM NG TO LP

INSTALLATION

INSTALLATION

CONVERSION KIT #521-969 FROM NG TO LP

LP Conversion instructions for BEFORE UNIT INSTALLATION.

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER, IF IN DOUBT DO NOT DO THIS CONVERSION!!

LP Conversion Kit Contains:

Qty.

Part #
Description

1

910-462

LP Conversion Coil

1

904-573

Cable Tie

1

910-037

LP Pilot Orifice

1

904-345

Orifice #53 (back)

1

904-241

Orifice #56 (front)

1

904-529

Allen Key

1

918-590

LP Conversion Decal

1

908-528

Red Propane Label

1918-596 Instruction Sheet

1)Remove the glass door.

a.Release the 2 door latches on the left and right side at the top of the firebox.

b. Swing the door out from the top and release the hinges on the left and right side of the door by lifting them up.

Hinge

Door

 

Front Burner Removed

c. Place the door on a soft surface to prevent

4) Remove the back burner by removing the
screw.
scratching.

 

2) Remove the grate by undoing the 2 screws

 

on the right and left side.

 

Latch Location

Latch

Grate

3) Remove the front burner by removing the screw.

Back Burner

5)Remove the rear log stand by removing the 4 screws.

Rear Log Stand
Front Burner

28

Regency® L676 Direct Vent Gas Fireplace

Page 28
Image 28
Regency L676 Installation, CONVERSION KIT #521-969FROM NG TO LP, LP Conversion Kit Contains, Part #, Description, screw