MAINTENANCE

VALVE TRAY REPLACEMENT

1)Remove the exterior brick panels.

2)Remove the glass door.

a.Release the 2 door latches on the left and right side at the top of the fi rebox.

Latch Location

Latch

b.Swingthedooroutfromthetopandrelease the hinges on the left and right side of the door by lifting them up.

3) Loosen the 2 screws that hold the left side

9) Remove the front burner by removing the

heat shield in place.

screw.

Heat

Shield

Front Burner

4)Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket (located directly above the heat shield).

Bracket

Front Burner Removed

10) Remove the back burner by removing the screw.

Hinge

Door

c.Place the door on a soft surface to prevent scratching.

Heat

Shield

5)Unplug the power source.

6)Remove the log set.

7)Remove the interior brick panels.

8)Remove the grate by undoing the 2 screws on the right and left side.

Back Burner

11)Remove the rear log stand by removing the 4 screws.

MAINTENANCE

Rear Log Stand

Grate

Regency® L676 Direct Vent Gas Fireplace

47

Page 47
Image 47
Regency L676 installation manual Valve Tray Replacement, Unplug the power source