Regency L676 Installation, LP Conversion Kit Contains, Part #, Description, Latch Location Latch

Models: L676

1 56
Download 56 pages 33.98 Kb
Page 31
Image 31
Heat

INSTALLATION

LP Conversion instructions for when unit is ALREADY INSTALLED.

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER, IF IN DOUBT DO NOT DO THIS CONVERSION!!

LP Conversion Kit Contains:

Qty.

Part #

Description

1

910-462

LP Conversion Coil

1

904-573

Cable Tie

1

910-037

LP Pilot Orifice

1

904-345

Orifice #53 (back)

1

904-241

Orifice #56 (front)

1

904-529

Allen Key

1

918-590

LP Conversion Decal

1

908-528

Red Propane Label

1

918-596

Instruction Sheet

c. Place the door on a soft surface to prevent

10) Remove the front burner by removing the

scratching.

screw.

4) Loosen the 2 screws that hold the left side

 

heat shield in place.

 

Heat

Shield

Front Burner

INSTALLATION

1)TurncontrolknobtotheOFFpositionand shut off the gas supply to the valve.

2)Remove exterior brick panels, if installed.

3)Remove the glass door.

a.Release the 2 door latches on the left and right side at the top of the firebox.

Latch Location

Latch

5)Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket (located directly above the heat shield).

Bracket

Heat

Shield

Front Burner Removed

11)Remove the back burner by removing the screw.

b. Swing the door out from the top and release the hinges on the left and right side of the door by lifting them up.

Hinge

Door

6)Unplug the power source.

7)Remove the log set, if installed.

8)Remove interior brick panels, if installed.

9)Remove the grate by undoing the 2 screws on the right and left side.

Back Burner

12)Remove the rear log stand by removing the 4 screws.

Rear Log Stand

Grate

Regency® L676 Direct Vent Gas Fireplace

31

Page 31
Image 31
Regency L676 Installation, LP Conversion Kit Contains, Part #, Description, Heat Shield Front Burner, Latch Location Latch