INSTALLATION
LP Conversion instructions for when unit is ALREADY INSTALLED.
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER, IF IN DOUBT DO NOT DO THIS CONVERSION!!
LP Conversion Kit Contains:
Qty. | Part # | Description |
1 | LP Conversion Coil | |
1 | Cable Tie | |
1 | LP Pilot Orifice | |
1 | Orifice #53 (back) | |
1 | Orifice #56 (front) | |
1 | Allen Key | |
1 | LP Conversion Decal | |
1 | Red Propane Label | |
1 | Instruction Sheet |
c. Place the door on a soft surface to prevent | 10) Remove the front burner by removing the |
scratching. | screw. |
4) Loosen the 2 screws that hold the left side |
|
heat shield in place. |
|
Heat
Shield
Front Burner
INSTALLATION
1)TurncontrolknobtotheOFFpositionand shut off the gas supply to the valve.
2)Remove exterior brick panels, if installed.
3)Remove the glass door.
a.Release the 2 door latches on the left and right side at the top of the firebox.
Latch Location
Latch
5)Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket (located directly above the heat shield).
Bracket
Heat
Shield
Front Burner Removed
11)Remove the back burner by removing the screw.
b. Swing the door out from the top and release the hinges on the left and right side of the door by lifting them up.
Hinge
Door
6)Unplug the power source.
7)Remove the log set, if installed.
8)Remove interior brick panels, if installed.
9)Remove the grate by undoing the 2 screws on the right and left side.
Back Burner
12)Remove the rear log stand by removing the 4 screws.
Rear Log Stand
Grate
Regency® L676 Direct Vent Gas Fireplace | 31 |