Regency L676 GAS Control Valve, Copy of Lighting Plate Instructions, Heat Shield

Models: L676

1 56
Download 56 pages 33.98 Kb
Page 41
Image 41

OPERATING INSTRUCTIONS

GAS CONTROL VALVE

The gas control knob is located on the right hand side of the firebox behind the right side exterior brick panel.

1)Remove the right side exterior brick panel.

Right Side Exterior Brick Panel

2)Loosen the 2 screws that hold the right side heat shield in place.

Heat

Shield

3)Lift the heat shield up and pull out slightly to clear the head screws and then hang it on the top bracket (located directly above the heat shield, close to the top of the fi rebox).

COPY OF LIGHTING PLATE INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. (Australia: AS5601-2004, New Zealand: NZS 5261)

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or gas supplier.

A)This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B)BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

-Do not try to light any appliance.

-Do not touch any electric switch, do not use any phone in your building.

-Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s instructions.

-If you cannot reach your gas supplier, call the fire department.

C)Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Forced or attempted repair may result in a fire or explosion.

D)Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

E)This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due to high surface temperatures keep children, clothing and furniture, gasoline and other liquids having flammable vapors away. Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

LIGHTING INSTRUCTIONS

STOP! Read the safety information above on this label.

1) Push in gas control knob slightly and turn clockwise

to “OFF”. Knob cannot be turned from

“PILOT” to “OFF” unless knob is pushed in slightly. Do not force.

PILOT BURNER

OFF

VEILLEUSE

 

THERMOPILE

ELEMENT

THERMO-

ELECTRIQUE

2)Wait five (5) minutes to clear out any gas. If you then smell gas STOP! Follow step “B” in the Safety Information above on this label. If you don’t smell gas, go to the next step.

3)Turn knob on gas control counterclockwise to“PILOT”.

4)Push in control knob all the way and hold in until the pilot lights up. Continue to hold the control knob in for about 20 seconds after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 1) to 4). If knob does not pop up when released, stop and immediately call your service technician or gas supplier. If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

5)Turn gas control knob counterclock-wise to “ON”.

6)Turn the unit on.

TO TURN OFF GAS APPLIANCE

1)Turn off the unit.

2)Push in the gas control knob slightly and turn clockwise to “OFF”. Do not force.

3)Turn off all electric power to the appliance if service is to be performed.

You may shut off the pilot during prolonged non use periods to conserve fuel.

DO NOT REMOVE THIS INSTRUCTION PLATE 918-583

OPERATION

Regency® L676 Direct Vent Gas Fireplace

41

Page 41
Image 41
Regency L676 GAS Control Valve, Copy of Lighting Plate Instructions, Right Side Exterior Brick Panel, Heat Shield