Regency L676S-NG1 Installation, Finishing, Non-Combustiblerequirements, Non-combustible, Diagram

Models: L676S-NG1

1 48
Download 48 pages 49.23 Kb
Page 12
Image 12
FINISHING

INSTALLATION

FINISHING

INSTALLATION

NON-COMBUSTIBLE REQUIREMENTS

 

 

 

44-1/2"

Metal

 

 

 

 

Stud

 

 

 

 

(1130mm)

 

 

 

 

 

 

15-9/16"

(392mm)

 

Non-combustible

 

 

 

Material

 

 

 

 

 

 

 

 

combustible Material -Non

31-5/8"

combustible Material -Non

47-5/8" (1209mm)

32-1/16”

(814mm)

(803mm)

29-1/16” (738mm)

 

 

 

Non-combustible Material

 

 

 

 

6-7/16"

Finished Floor

3"

 

 

(163mm)

 

 

(76mm)

Diagram 1

Note: All non-combustible facing material should butt up cleanly to the flanges around the firebox opening.

Rough edges may be visible, from an angle, through the 1/2" gap behind the faceplate.

To obtain a clean edge, facing material edges may be finished with a J-style trim or metal cornerbead (both materials available at your local building or hardware outlet) see diagram 2.

Important: Materials used must be NON-COMBUSTIBLE

1)Finishing material such as tile, river rock, etc. must not protrude beyond the front facing flanges on all 4 sides of the firebox opening.

2) If material such as brick, stone, etc. extends past the faceplate depth, when finishing around the faceplate, the minimum opening dimension noted below (Diagram 3) must be adhered to - to ensure the faceplate can be removed.

36 -1/4”

34-9/16”

Diagram 3

Important:

A3/4" gap must be maintained all around the outer edge of the faceplate and the edge of any finishing material thicker than 1-1/4" (see diagram 4).

This gap is required to facilitate the installation of the faceplate and to ensure the removal of the faceplate for service access.

3/4"

Finishing Material

(thickness + 1-1/4")

Diagram 4

Diagram 2

12

Regency® L676S Direct Vent Gas Fireplace

Page 12
Image 12