Regency L676S-NG1 Installation, Manufactured Mobile Home Additional Requirements, Finished Floor

Models: L676S-NG1

1 48
Download 48 pages 49.23 Kb
Page 8
Image 8
MANUFACTURED

INSTALLATION

INSTALLATION

9)Test Gas Pressure (Refer to "Gas Pipe Pres- sure Testing" section).

10)Install standard and optional features. Refer to the following sections:

a)Inside Panels

b)Glass Crystals or Ceramic Stones

c)Remote Control - refer to "Matching Remote Handset & Control Box ID Code" section.

d)Outer Faceplate

11)Final check.

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to customer.

This includes:

1)Clocking the appliance to ensure the correct firing rate (rate noted on label 29,000 (NG) Btu/h, 26,000 (LP) Btu/h) after burning appliance for 15 minutes.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

3)The L676S Direct Vent Gas Fireplace can be installed in a recessed position or framed out into the room as in A, B, C and D. See Diagram 1.

A) Flat on Wall

B)Flat on Wall Corner

C)Recessed into

Wall/Alcove

D) Corner

Diagram 1

4)This appliance is Listed for bedroom installations using the standard Remote (millivolt thermostat system). Some areas may have further requirements, check local codes before installation.

5)The L676S Direct Vent Gas Fireplace is approved for alcove installations, see "Clearances" section for details.

6)We recommend that you plan your installation on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have an authorized inspector, dealer, or installer review your plans before installation.

Note: For vent terminations refer to "Exterior Vent Termination Locations" section.

HEAT RELEASE KIT

The Heat Release Kit expels warm air from the fireplace to the outside of the building, allowing the fireplace to be operated with less heat entering the room. The kit may be used on either the left or right side.

See Heat Release installation manual for complete details and clearances from side only.

FINISHED FLOOR

The maximum height that combustible floor can be brought above the base of the unit is 0".

Note: If finished floor is any higher than the base of the unit, the facepate will not fit into place.

1)Ensure that structural members are not cut or weakened during installation.

2)Ensure proper grounding using the #8 ground lug provided. See "Wiring Diagram" section.

LOCATING YOUR

GAS FIREPLACE

1)When selecting a location for your fireplace, ensure that the clearances are met.

2)The appliance must be installed on a flat, solid, continuous surface (e.g. wood, metal, concrete).This may be the floor, or raised up on a platform to enhance its visual impact. The appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

HEATWAVE

DUCT KIT

The HeatWave Air Duct Kit increases the effectiveness of your fireplace by dispersing warm air from the fireplace to remote locations in the same room or other rooms in your home.

Up to two kits may be installed on the fireplace. Please Note: Only 1 HeatWave kit may be operated at one time.

See HeatWave installation manual for complete details and clearances from side only.

The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details.

8

Regency® L676S Direct Vent Gas Fireplace

Page 8
Image 8
Regency L676S-NG1 Installation, Manufactured Mobile Home Additional Requirements, Heat Release Kit, Finished Floor