Image 23
Vertical Venting with Three (3) 90o Elbows

INSTALLATION

Vertical Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

V H + H1 V + V1 With these options, max. total

A)2' Min. 2' Max. 4' Min. pipe length is 30 feet with min. of 9 feet total vertical and max.

B)3' Min. 4' Max. 6' Min. 8 feet total horizontal.

C)4' Min. 5' Max. 7' Min.

D)5' Min. 6' Max. 8' Min. Please note min. 1 foot

E)6' Min. 8' Max. 9' Min. between 90o elbows is required.

VENT RESTRICTOR SETTING:

Vent restrictor factory set at Set 1, no adjustment required.