INSTALLATION

CONVERSION KIT #526-969 FROM NG TO LP

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER, IF IN DOUBT DO NOT DO THIS CONVERSION!!

INSTALLATION

LP Conversion Kit Contains:

Qty.

Part #

Description

1

910-101

Orifice SIT Pilot LP #35

1

910-037

LP Pilot Orifice

1

908-528

Red Propane Label

1

904-345

Orifice #53

1

904-529

Allen Key 5/32

1

918-590

LP Conversion Decal

1

918-764

Instruction Sheet

1906-182 4 x 6 Ziplock Case.

1)Remove the faceplate (see page 35).

2)Remove the glass door.

a. Release the 2 door latches on the left and right side at the top of the firebox.

Latch Location

Latch

b. Swing the door out from the top and release the hinge on the left side of the door and lift out off hinge.

Hinge with door removed.

c.Place the door on a soft surface to prevent scratching.

3)Lift off the Pilot Shield Cover Plate to expose 2 bolts.

Pilot Shield Cover Plate

Bolts

4)Remove the 2 bolts to release the burner.

6)Remove the burner orifice with a 1/2" wrench. Use another wrench to hold onto the elbow behind the orifice. Replace the NG burner orifice with LP orifice #53.

Burner Orifi ce

7)Remove the NG pilot orifice with the 5/32 Allen Key and replace with LP pilot orifice.

8)Reinstall the pilot cap.

Pilot Cap

5) Carefully lift out burner.

Door

30

Regency® L676S Direct Vent Gas Fireplace

Page 30
Image 30
Regency L676S-NG1 installation manual Conversion KIT #526-969 from NG to LP, LP Conversion Kit Contains Qty Description