INSTALLATION
8)Turn control knob to the “OFF” position.
9)Remove the black protection cap by hand from the
Fig.1
10)Insert a 5/32” or 4mm Allen wrench into the hexagonal
13)Using the Allen wrench as shown in Fig.4, rotate the screw clockwise until snug, do not overtighten.
Fig.4
WARNING!
Do not overtighten the screw. Recommended to grip
the wrench by the short side.
14)Verify that if the conversion is from NG to LPG, the screw must be
16)Install the enclosed identification label to the valve body where it can be easily seen.
17)Attach the LP conversion decal near or on top of the serial no. decal.
18)Replace yellow "Natural Gas" label with red "Propane" label.
19)Adjust the burner aeration setting to the LP setting (5/16") and
20)
21)
22)
23)
24)Continue with completing unit installation.
NOTE: Once the unit has been installed;
a) Turn on the gas supply and check for gas |
leaks. |
b) Check the inlet and outlet pressures. |
INSTALLATION
Red
LPG Configuration
c) Check operation of flame control using |
the remote control. |
d) Check for proper flame appearance. |
Fig.2
11)Check that the screw is clean and if necessary remove dirt.
12)Flip the screw (Fig. 3).
Fig.3
Fig.5
15)
Fig.6
WARNING!
Also check that the pilot and
main burner injectors
are appropriate for the gas type.
Installer Notice:
These instructions must be left with the appliance.
Regency® L676S Direct Vent Gas Fireplace | 31 |