INSTALLATION

8)Turn control knob to the “OFF” position.

9)Remove the black protection cap by hand from the high-low knob (Fig.1).

Fig.1

10)Insert a 5/32” or 4mm Allen wrench into the hexagonal key-way of the screw (Fig. 2), rotate it counter-clockwise until it is free and extract it.

13)Using the Allen wrench as shown in Fig.4, rotate the screw clockwise until snug, do not overtighten.

Fig.4

WARNING!

Do not overtighten the screw. Recommended to grip

the wrench by the short side.

14)Verify that if the conversion is from NG to LPG, the screw must be re-assembled with the red o-ring visible (Fig. 5).

16)Install the enclosed identification label to the valve body where it can be easily seen.

17)Attach the LP conversion decal near or on top of the serial no. decal.

18)Replace yellow "Natural Gas" label with red "Propane" label.

19)Adjust the burner aeration setting to the LP setting (5/16") and

re-install the burner tube.

20)Re-install the burner.

21)Re-install the Pilot Shield cover plate.

22)Re-install the glass door.

23)Re-install the faceplate

24)Continue with completing unit installation.

NOTE: Once the unit has been installed;

a) Turn on the gas supply and check for gas

leaks.

b) Check the inlet and outlet pressures.

INSTALLATION

Red o-ring visible

LPG Configuration

c) Check operation of flame control using

the remote control.

d) Check for proper flame appearance.

Fig.2

11)Check that the screw is clean and if necessary remove dirt.

12)Flip the screw (Fig. 3).

Fig.3

Fig.5

15)Re-assemble the black protection cap (Fig. 6).

Fig.6

WARNING!

Also check that the pilot and

main burner injectors

are appropriate for the gas type.

Installer Notice:

These instructions must be left with the appliance.

Regency® L676S Direct Vent Gas Fireplace

31

Page 31
Image 31
Regency L676S-NG1 installation manual Leaks