INSTALLATION

INSTALLATION

Horizontal Venting with Two (2) 90o Elbows

H1

V

One 90o elbow = Two 45o elbows.

Option

 

V

 

H + H1

W i t h t h e s e o p t i o n s,

 

A)

2'

Min.

 

4' Max.

 

 

maximum total pipe length

 

B)

3'

Min.

 

6' Max.

 

 

is 30 feet with minimum

 

 

 

 

 

 

 

 

C)

4'

Min.

 

8' Max.

of 6 feet total vertical and

 

D)

5'

Min.

 

 

 

maximum 10 feet total

 

 

9' Max9'Max.

 

 

 

 

 

 

 

horizontal.

 

E)

6' Min.

10' Max.

 

 

 

 

 

 

 

 

 

 

 

Please note minimum 1 foot between 90o elbows is required.

VENT RESTRICTOR SETTING:

Vent restrictor factory set at Set 1, no adjustment required.

Horizontal Venting with Three (3) 90o Elbows

H1

V1

One 90o elbow = Two 45o elbows.

H

V

Option V

H

V + V1 H + H1

A)2' Min. 1' Max. 3' Min. 2' Max.

B)2' Min. 2' Max. 5' Min. 4' Max.

C)3' Min. 2' Max. 7' Min. 5' Max.

D)4' Min. 3 Max. 9' Min. 6' Max.

E)5' Min. 4' Max. 10' Min. 7' Max.

F)6' Min. 6' Max. 11' Min. 9' Max.

With these options, max. total pipe length is 30 feet with min. of 11 feet total vertical and max. 9 feet total horizontal.

Please note min. 1 foot between 90o elbows is required.

VENT RESTRICTOR SETTING:

Vent restrictor factory set at Set 1, no adjustment required.