INSTALLATION
SAFETY LABEL
This is a copy of the label that accompanies
each
NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
COPY OF SAFETY DECAL
For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli-
ances individual manual
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.
342
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ETIQUETTE`
342
Serial No. / No de serie
Listed: VENTED GAS FIREPLACE HEATER
Tested to: ANSI
Certified for / Certifiée pour: CANADA AND U.S.A.
WN # 16074
| NATURAL GAS FIREPLACE: MODEL | ||||
L676SNG1- Model/Modele: | Factory Equipped For Altitude | ||||
Min. Supply Pressure | 5“ | WC | (1.25 kpa) | ||
| |||||
| Low Setting Man. Pressure | 1.6" | WC | (0.39 kpa) | |
| Max. Manifold Pressure | 3.5" | WC | (0.87 kpa) | |
| Orifice Size | #37 | DMS |
| |
| Minimum Input | 19,500 | Btu/h | (5.71 kW) | |
| Maximum Input | 29,000 | Btu/h | (8.49 kW) |
| PROPANE GAS FIREPLACE: MODEL | ||||
L676SLP1- Model/Modele: | Factory Equipped For Altitude | ||||
Min. Supply Pressure | 12" | WC | (2.98 kpa) | ||
| |||||
| Low Setting Man. Pressure | 6.4" | WC | (1.59 kpa) | |
| Max. Manifold Pressure | 10" | WC | (2.49 kpa) | |
| Orifice Size | #53 | DMS |
| |
| Minimum Input | 21,000 | Btu/h | (6.15 kW) | |
| Maximum Input | 26,000 | Btu/h | (7.61 kW) |
VENTED GAS FIREPLACE HEATER
This appliance must be installed in accordance with the manufacturer’s installation instructions and with local codes, if any; if none, follow the current ANSI Z223.1 in the USA or the current CAN
This vented gas fireplace heater is not for use with air filters.
For Manufactured Home Installation: This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installation, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used (Kit
Certified for use with Heat Wave (Kit
For use with glass doors certified with the appliance only.
Electrical Supply: 6.0 VDC
NOT FOR USE WITH SOLID FUEL
Minimum Clearances to Combustibles from Fireplace Opening
Side Walls | *A |
|
| ||
Ceiling | B | 52" | (813mm) |
| B |
D | F | ||||
Min. Mantel Height | C |
| |||
|
| ||||
Max. Mantel Depth | **D | 13” | (330mm) |
| A |
Alcove Width | E | 84" | (2134mm) |
| |
C |
| ||||
Alcove Depth | F | 36" | (914mm) |
|
|
Finished Floor | G | 3” | (76mm) | G |
|
|
|
|
|
| E |
Refer to Manual for complete Clearance Details
*Alcove side wall must have a min. of
**Mantel depth taken at
FPI Fireplace Products International Ltd., Delta BC, CANADA |
|
MADE IN CANADA / FABRIQUE AU CANADA |
4 | Regency® L676S Direct Vent Gas Fireplace |