INSTALLATION

SAFETY LABEL

This is a copy of the label that accompanies

each L676S-NG1 and L676S-LP1 Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review.

NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

COPY OF SAFETY DECAL

For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts.

For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appli-

ances individual manual shut-off must be a t-handle type valve.

The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.

342

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ETIQUETTE`

342

Serial No. / No de serie

Listed: VENTED GAS FIREPLACE HEATER

Tested to: ANSI Z21.88a-2007/ CSA 2.33a-2007,

CAN/CGA-2.17-M91

Certified for / Certifiée pour: CANADA AND U.S.A.

WN # 16074

 

NATURAL GAS FIREPLACE: MODEL L676S-NG1

L676SNG1- Model/Modele:

Factory Equipped For Altitude 0-4500ft. (0-1372m)

Min. Supply Pressure

5“

WC

(1.25 kpa)

 

 

Low Setting Man. Pressure

1.6"

WC

(0.39 kpa)

 

Max. Manifold Pressure

3.5"

WC

(0.87 kpa)

 

Orifice Size

#37

DMS

 

 

Minimum Input

19,500

Btu/h

(5.71 kW)

 

Maximum Input

29,000

Btu/h

(8.49 kW)

 

PROPANE GAS FIREPLACE: MODEL L676S-LP1

L676SLP1- Model/Modele:

Factory Equipped For Altitude 0-4500ft. (0-1372m)

Min. Supply Pressure

12"

WC

(2.98 kpa)

 

 

Low Setting Man. Pressure

6.4"

WC

(1.59 kpa)

 

Max. Manifold Pressure

10"

WC

(2.49 kpa)

 

Orifice Size

#53

DMS

 

 

Minimum Input

21,000

Btu/h

(6.15 kW)

 

Maximum Input

26,000

Btu/h

(7.61 kW)

VENTED GAS FIREPLACE HEATER

This appliance must be installed in accordance with the manufacturer’s installation instructions and with local codes, if any; if none, follow the current ANSI Z223.1 in the USA or the current CAN 1-B149 in Canada.

This vented gas fireplace heater is not for use with air filters.

For Manufactured Home Installation: This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installation, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used (Kit #526-969).

Certified for use with Heat Wave (Kit #946-556).

For use with glass doors certified with the appliance only.

Electrical Supply: 6.0 VDC

NOT FOR USE WITH SOLID FUEL

Minimum Clearances to Combustibles from Fireplace Opening

Side Walls

*A

14-3/4" (375mm)

 

 

Ceiling

B

52"

(813mm)

 

B

D

F

Min. Mantel Height

C

16-1/2" (419mm)

 

 

 

Max. Mantel Depth

**D

13”

(330mm)

 

A

Alcove Width

E

84"

(2134mm)

 

C

 

Alcove Depth

F

36"

(914mm)

 

 

Finished Floor

G

3”

(76mm)

G

 

 

 

 

 

 

E

Refer to Manual for complete Clearance Details

*Alcove side wall must have a min. of 14-3/4” (375mm) clearance on one side.

**Mantel depth taken at 26-1/2” (673mm) from front facing.

FPI Fireplace Products International Ltd., Delta BC, CANADA

 

MADE IN CANADA / FABRIQUE AU CANADA

918-760

4

Regency® L676S Direct Vent Gas Fireplace

Page 4
Image 4
Regency L676S-NG1 installation manual Safety Label, Copy of Safety Decal, Serial No. / No de serie