Regency P48-NG Venting Arrangements - Horizontal Terminations, Regency Direct Vent System Flex

Models: P48-NG P48-LP

1 48
Download 48 pages 12.3 Kb
Page 14
Image 14
VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS

INSTALLATION

VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS

SIMPSON DURA-VENT DIRECT VENT GS SYSTEM and

REGENCY DIRECT VENT SYSTEM (FLEX)

(Propane & Natural Gas)

The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45o and one 90o elbow (two 45o elbows equal one 90o elbow).

Note: Must use optional flue adapter (Part # 370-994) when using Simpson Dura-Vent pipe. (Refer to page 13.)

Simpson Dura-Vent 5" inner diameter 8" outer diameter

Regency Flex Vent 5" inner diameter 8" outer diameter

A vent guard should be used when- ever the termination is lower than the specified minimum or as per local codes.

Note: Regency Direct Vent System (Flex) is only approved for hor- izontal terminations.

Maintain clearances to combustibles as listed on pages 6 to 9.

Horizontal vent must be supported every 3 feet.

Firestops are required at each floor level and whenever passing through a wall.

14

Regency P48 Zero Clearance Direct Vent Gas Fireplace

Page 14
Image 14
Regency P48-NG, P48-LP Venting Arrangements - Horizontal Terminations, SIMPSON DURA-VENTDIRECT VENT GS SYSTEM and