OPERATING INSTRUCTIONS

OPERATING

INSTRUCTIONS

1)Read and understand these instructions before operating this appliance.

2)Check to see that all wiring is correct and enclosed to prevent possible shock.

3)Check to ensure there are no gas leaks.

4)Make sure the glass in the door frame is properly positioned. Never operate the ap- pliance with the glass removed.

5)Verify that the venting and cap are unob- structed.

6)Ensure that the brick panels are installed.

7)Verify log placement. If the pilot cannot be seen when lighting the unit, the logs have been incorrectly positioned.

8)The unit should never be turned off, and on again without a minimum of a 60 second wait.

LIGHTING

PROCEDURE

IMPORTANT

To ignite or reignite the pilot,

you must first release the

tension springs below the door.

Only when the pilot holds, without pressure being applied to the control knob, reapply the tension springs to the door. The unit must not be operated with the tension springs unattached.

IMPORTANT Gas cock knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed.

1)Turn burner OFF using "ON/OFF" switch.

2)Turn gas control knob so indicator points to "OFF" position and allow 5 minutes for any gas in the combustion chamber to escape.

3)Turn gas control knob counterclockwise so indicator points to the "PILOT" position. Depress the gas control knob fully. De- press the igniter button several times until the pilot lights. After approximately one minute, release the gas control knob. The pilot flame should continue to burn. If the pilot does not remain lit, repeat operation allowing a longer period before releasing gas control knob.

4)When the pilot stays lit, turn the gas knob further counterclockwise to the "ON" po- sition.

5)Use the wall switch, thermostat or remote control to turn on the unit.

6)Rotate the flame height regulator to adjust the flame height higher or lower.

SHUTDOWN

PROCEDURE

1)Use the wall switch, thermostat or remote control to turn off the main burner.

2)Turn the main gas control clockwise to the "OFF" position to turn off the pilot.

3)Turn off all electric power to appliance if service is to be performed.

FIRST FIRE

DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.

The first fire in your stove is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fireplace for at least four (4) hours the first time before you use it with the fan on.

When first operated, the unit will release an odour caused by the curing of the paint, the burning off of any oils remaining from manu- facturing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours.

Note: When the glass is cold and the appliance is lit, it may cause con- densation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

During the first few fires, a white film may develop on the glass front as part of the curing process. The glass should be cleaned after the unit has cooled down or the film will bake on and become very difficult to remove. Use a non-abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT.

AERATION

ADJUSTMENT

The air shutter can be adjusted by moving the adjusting wire up or down. The wire is ac- cessed through the bottom louver opening. Open the air shutter for a blue flame or close for a more yellow flame. The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude.

Minimum Air Shutter Opening:

3/16"

Natural Gas

Fully Open

Propane

CAUTION: Carbon will be produced if air shutter is closed too much.

Note: Any damage due to carboning re- sulting from improperly setting the aeration controls is NOT covered under warranty.

Adjustment Wire - Pull down to open or

push up to close aeration cap.

Closed - Tall yellow

Open - Short Blue

Note: Aeration Adjustment should only be performed by an authorized Regency Installer at the time of installation or service.

Regency P48 Zero Clearance Direct Vent Gas Fireplace

35

Page 35
Image 35
Regency P48-LP, P48-NG installation manual Operating Instructions

P48-NG, P48-LP specifications

The Regency P48-NG and P48-LP are notable entrants in the world of propane heating solutions, designed to meet the needs of both residential and commercial users. These high-efficiency models combine modern technology with user-friendly features, making them a popular choice for those looking to enhance their heating systems.

One of the standout features of the P48-NG and P48-LP is their powerful heating capacity. Both models are engineered to deliver consistent warmth, effectively heating spaces of various sizes. The P48-NG operates efficiently on natural gas, while the P48-LP is designed for use with liquid propane, providing versatility depending on available fuel sources. Suitable for a wide range of applications, these models can easily accommodate homes, workshops, and even larger commercial spaces.

In terms of technology, the Regency P48 series employs advanced burner systems to optimize combustion and maximize energy efficiency. This ensures that users experience lower energy bills while also reducing their carbon footprint. The units also feature a patented air mixing system that contributes to cleaner burning and improved airflow, resulting in a more comfortable and uniform heat distribution throughout the space.

Another significant characteristic of the P48-NG and P48-LP is their remarkable design. The models boast a sleek, contemporary appearance that fits seamlessly into a variety of decors, from rustic to modern. The large viewing area offers an impressive flame presentation, creating a mesmerizing ambiance that enhances the living space.

Additionally, safety features are paramount in the design of the Regency P48 series. Both models include advanced safety controls, such as an automatic shut-off system in the event of gas leaks or operational anomalies, ensuring peace of mind for users. The installation of these units is straightforward, and they comply with current safety standards, making them a reliable choice for any environment.

The P48-NG and P48-LP also incorporate user-friendly controls that allow for easy temperature adjustments. Remote control options are available, adding convenience for users who wish to manage their heating system from a distance. With all these features combined, the Regency P48-NG and P48-LP are innovative heating solutions that embody efficiency, safety, and style, catering to the modern heating needs of today’s users.