Regency P48-LP, P48-NG installation manual •Vent must be supported at offsets

Models: P48-NG P48-LP

1 48
Download 48 pages 12.3 Kb
Page 19
Image 19
Manual background

INSTALLATION

The P48 is approved for a maximum 40 ft. straight vertical, with Simpson Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas, as per diagram.

The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations with Simpson Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas. Maximum two 45o elbows allowed.

Vent must be supported at offsets

• Firestops are required at each floor level and whenever passing through a wall.

Maintain clearances to combustibles as listed on pages 6 to 9.

Regency P48 Zero Clearance Direct Vent Gas Fireplace

19