INSTALLATION

IMPORTANT:

SAVE THESE

INSTRUCTIONS

The P48-NG/P48-LP Direct Vent Fireplace must be installed in accordance with these instruc- tions. Carefully read all the instructions in this manual first. Consult the "authority having juris- diction" to determine the need for a permit prior to startingtheinstallation.Itistheresponsibilityofthe installer to ensure this fireplace is installed in compliance with manufacturers instructions and all applicable codes.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

INSTALLATION AND REPAIR SHOULDBEDONEBYANAUTHOR- IZED SERVICE PERSON. THE AP- PLIANCESHOULDBEINSPECTED BEFORE USE AND AT LEAST AN- NUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FRE- QUENT CLEANING MAY BE RE- QUIRED DUE TO EXCESSIVE LINT FROMCARPETING,BEDDINGMA- TERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPART- MENTS,BURNERSANDCIRCULAT- ING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LO- CATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILLVOIDYOURWARRANTYAND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDRENANDADULTSSHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERA- TURES, ESPECIALLY THE FIRE- PLACE GLASS, AND SHOULD STAYAWAYTOAVOIDBURNSOR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISEDWHEN THEYAREINTHESAMEROOMAS THE APPLIANCE.

CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACEDONORNEARTHEAPPLI- ANCE.

GENERAL SAFETY

INFORMATION

1)The appliance installation must conform with local codes or, in the absence of local codes, with the current Canadian or Nation- al Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.

2)The appliance when installed, must be elec- trically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/ NFPA 70 or CSA C22.1 Canadian Electrical Code.

3)See general construction and assembly instructions. The appliance and vent should be enclosed.

4)This appliance must be connected to the specified vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fitted as per Venting instructions.

5)Inspect the venting system annually for blockage and any signs of deterioration.

6)Venting terminals shall not be recessed into a wall or siding.

7)Any safety glass removed for servicing must be replaced prior to operating the appliance.

8)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fireplace.

9)Wear gloves and safety glasses for pro- tection while doing required maintenance.

10)Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination.

11)Under no circumstances should this appli- ance be modified. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

12)Installation and any repairs to this appliance should be done by an authorized service person. A professional service person should be called to inspect this appliance

annually. Make it a practice to have all of your gas appliances checked annually.

13)Do not slam shut or strike the glass door.

14)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

15)The appliance area must be kept clear and free of combustible materials, (gases and other flammable vapours and liquids).

Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

INSTALLATION

CHECKLIST

1)Locate appliance

a)Room location, page 6

b)Clearances to Combustibles, page 7

c)Mantel Clearances, page 8

d)Framing & Finishing Requirements, page 9

e)Venting Requirements, pages 10-18.

2)Assemble Top Facing Support and Side Nailing Strips, page 10.

NOTE: must be done before installing unit into fireplace.

3)Install venting, pages 20-21.

4)Make gas and electrical connections. Test the pilot. Must be as per diagram. Page 23.

5)Test Gas Pressure. Page 23.

6)Install brick panels (optional), page 24.

7)Install Flush Door Front (Standard) and optional Flush Gold Trim, page 28.

8)Install Optional Bay Front and optional Bay Gold Trim, page 29.

9)Install Louvers (Flush or Bay), pages 28-29.

10)Installation of Wall Switch, Remote Control, or Wall Thermostat, page 31.

11)Final check.

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to customer.

Regency P48 Zero Clearance Direct Vent Gas Fireplace

5

Page 5
Image 5
Regency P48-LP, P48-NG Save These Instructions, Before YOU Start, General Safety Information, Installation Checklist

P48-NG, P48-LP specifications

The Regency P48-NG and P48-LP are notable entrants in the world of propane heating solutions, designed to meet the needs of both residential and commercial users. These high-efficiency models combine modern technology with user-friendly features, making them a popular choice for those looking to enhance their heating systems.

One of the standout features of the P48-NG and P48-LP is their powerful heating capacity. Both models are engineered to deliver consistent warmth, effectively heating spaces of various sizes. The P48-NG operates efficiently on natural gas, while the P48-LP is designed for use with liquid propane, providing versatility depending on available fuel sources. Suitable for a wide range of applications, these models can easily accommodate homes, workshops, and even larger commercial spaces.

In terms of technology, the Regency P48 series employs advanced burner systems to optimize combustion and maximize energy efficiency. This ensures that users experience lower energy bills while also reducing their carbon footprint. The units also feature a patented air mixing system that contributes to cleaner burning and improved airflow, resulting in a more comfortable and uniform heat distribution throughout the space.

Another significant characteristic of the P48-NG and P48-LP is their remarkable design. The models boast a sleek, contemporary appearance that fits seamlessly into a variety of decors, from rustic to modern. The large viewing area offers an impressive flame presentation, creating a mesmerizing ambiance that enhances the living space.

Additionally, safety features are paramount in the design of the Regency P48 series. Both models include advanced safety controls, such as an automatic shut-off system in the event of gas leaks or operational anomalies, ensuring peace of mind for users. The installation of these units is straightforward, and they comply with current safety standards, making them a reliable choice for any environment.

The P48-NG and P48-LP also incorporate user-friendly controls that allow for easy temperature adjustments. Remote control options are available, adding convenience for users who wish to manage their heating system from a distance. With all these features combined, the Regency P48-NG and P48-LP are innovative heating solutions that embody efficiency, safety, and style, catering to the modern heating needs of today’s users.