INSTALLATION
OPTION 1: | OPTION 2: | OPTION 3: |
REMOTE CONTROL | WALL SWITCH | WALL THERMOSTAT |
Can be used with Option 2 or 3 | Can be used with Option 1 or 3 |
but not both. | but not both. |
Can be used with Option 1 or 2 but not both.
Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty.
The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.
1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very im- portant). Run wires from the fireplace to that location. Use the Thermostat Wire Ta- ble.
2)Connect the two wires to the gas valve. See diagram.
CAUTION
Do not connect millivolt remote
control wires to a 120V wire.
1)Run the supplied 15' of wire through the back gas inlet opening. Be careful not to damage wire.
Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run, use the Thermostat Wire Table.
2)Connect the wire to the supplied wall switch and install into the receptacle box.
CAUTION
Do not connect millivolt
wall switch wire to a 120V wire.
A wall thermostat may be installed if desired, connect the wires as per the wiring diagram on page 29. Use the table below to determine the maximum wire length.
Note: Preferable if the thermostat is in- stalled on an interior wall.
Regency offers an optional programmable ther- mostat but any
CAUTION
Do not connect millivolt
wall thermostat wires
to a 120V wire.
Thermostat Wire TableRecommended Maximum Lead Length
Thermostat
Wire Size | Max. Length |
|
14 GA. | 50 Ft. |
|
16 GA. | 32 Ft. |
|
18 GA. | 20 Ft. |
|
20 GA. | 12 Ft. |
|
22 GA. | 9 Ft. |
|
|
|
|
3)Install 3 AAA alkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.