Regency P48-NG Standard Flush Door, Flush Louvers, Optional Flush Trim, bottom flush louver

Models: P48-NG P48-LP

1 48
Download 48 pages 12.3 Kb
Page 28
Image 28
STANDARD

INSTALLATION

STANDARD

FLUSH DOOR

The standard flush door comes with a black frame. To install the frame, simply hook the top door flange onto the top of the unit and swing the door towards the unit, diagram 1.

FLUSH LOUVERS

1)Install the top louver by sliding the two bracket clips into the brackets located un- derneath the top of the firebox.

2)Install the bottom louver by folding the lou- ver down and then sliding the Bottom Lou- ver bracket down onto the 2 pins on the base of the unit (diagram 1). Secure with 1 screw as per diagram 2.

Burner ON/OFF control box attached to

bottom flush louver.

Diagram 1

Be careful that the glass gasket does not roll up; there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit. Diagram 2.

 

 

Optional Flush Trim

 

 

Attach the round magnets to the back of the top

Diagram 1

Diagram 2

trim piece and to the bottom trim piece, then

 

 

attach trim to the top and bottom of Flush door.

Note: Top and bottom louvers are different.

Diagram 2

Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket. Repeat for 2nd and 3rd spring. See diagram 3.

Diagram 3

NOTE: Springs must always be OVER
not under the gas line.

To remove the flush door, reverse the above steps.

3)Open the bottom louver. Pull the Burner ON/ OFF control box from inside the bottom of the fireplace. Using the 2 screws on the louver, secure the control box in place.

Screws on

Burner ON/OFF

louver bracket

control box

28

Regency P48 Zero Clearance Direct Vent Gas Fireplace

Page 28
Image 28
Regency P48-NG Standard Flush Door, Flush Louvers, Optional Flush Trim, Burner ON/OFF control box attached to, Diagram