Regency P48-NG Venting, Regency Direct Vent System Flex Horizontal, Terminations Only, Notes

Models: P48-NG P48-LP

1 48
Download 48 pages 12.3 Kb
Page 12
Image 12
VENTING

INSTALLATION

VENTING

Regency Direct Vent System (Flex) Horizontal

Terminations Only

These venting systems, in combination with the P48 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram on page 11.

Regency Direct Vent (Flex) System Termina- tion Kit (Part# 946-615) includes all the parts needed to install the P48 with a maximum run of 4 feet.

1) 8" dia. flexible liner (4 ft. length)

2)5" dia. flexible liner (4 ft. length)

3) spring spacers (4)

4) thimble (2)

5)AstroCap XL termination cap (1)

6) screws (12)

7) tube of Mill Pac (1)

8)plated screws (8)

9)screws #8 x 1-1/2" Drill Point, Stainless Steel (4)

10)vinyl siding standoff

If longer runs are needed, the Regency Direct Vent system (Flex) Part# 946-616 includes all the parts needed to install the P48 with a maximum 10' run.

1) 8" dia. flexible liner (10 ft. length)

2)5" dia. flexible liner (10 ft. length)

3)spring spacers (7)

4)thimble (2)

5) AstroCap XL termination cap (1)

6)screws (12)

7)tube of Mill Pac (1)

8) plated screws (8)

9) screws #8 x 1-1/2" Drill Point, Stainless Steel (4)

10)vinyl siding standoff

Notes:

1)Liner sections should be continuous without any joints or seams.

2)Only Flex pipe purchased from Regency may be used for Flex installations.

3)If you are installing the P48 into a Regency Mantel Kit, use the minimum horizontal vent height (centre-line of 43"). Remember to include the mantel base in your calculations and to maintain the 2-1/2" clearance to the underside of the mantel top.

12

Regency P48 Zero Clearance Direct Vent Gas Fireplace

Page 12
Image 12
Regency P48-NG, P48-LP installation manual Venting, Regency Direct Vent System Flex Horizontal, Terminations Only, Notes