Regency P48-LP, P48-NG Vertical Venting with Three 3 90o Elbows, Option, H + H1 V +

Models: P48-NG P48-LP

1 48
Download 48 pages 12.3 Kb
Page 17
Image 17
Vertical Venting with Three (3) 90o Elbows

INSTALLATION

Vertical Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

H

V

H + H1

V + V1

With these options, max. total

A)

1' Max.

1' Min.

3' Max.

3' Min.

pipe length is 30 feet with min.

B)

2' Max.

2' Min.

4' Max.

5' Min.

of 11 feet total vertical and

C)

3' Max.

3' Min.'

5' Max.

7' Min.

max. 7 feet total horizontal.

 

 

 

 

 

Please note min. 1 foot

D)

4' Max.

4' Min.

6' Max.

9' Min.

between 90o elbows is re-

E)

5' Max.

5' Min.

7' Max.

11' Min.

quired.

 

 

 

 

 

 

Vertical Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option V

H + H1 V + V1

A)2' Min. 3' Max. 4' Min.

B)3' Min. 4' Max. 6' Min.

C)4' Min. 5' Max. 7' Min.

D)5' Min. 6' Max. 8' Min.

E)6' Min. 7' Max. 9' Min.

F)7' Min. 8' Max. 10' Min.

With these options, max. to- tal pipe length is 30 feet with min. of 10 feet total vertical and max. 8 feet total horizon- tal.

Please note min. 1 foot between 90o elbows is re- quired.