Regency P48-LP, P48-NG Requirements, Exterior, Vent terminal, Air supply outlet

Models: P48-NG P48-LP

1 48
Download 48 pages 12.3 Kb
Page 11
Image 11
EXTERIOR

Regency P48 Zero Clearance Direct Vent

Vertical Termination

24"

D

E

V

Inside corner detail

G VENTVent terminal

V

A

Vertical

Termination

24"

18"

V

EXTERIOR

Gas Fireplace

B

V

M

.

C

 

V

Fixed

 

Closed

 

 

F

V

Openable

 

 

B

V

Openable

B

Fixed Closed

 

H

V

 

B

N

 

L

VENT

B

B

V

K

A

 

j

 

 

 

A

 

V

A

TERMINATION

V

Vent terminal

A

Air supply outlet

 

Area where terminal is not permited

 

 

 

 

A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm)

H= Not to be installed above a meter/regulator assembly within (3'/90cm) horizontally from

B= Clearance to window or door that may be opened *(12"/30cm)

 

the centerline of the regulator.

C= Clearance to permanently closed window *(min. 12"/30cm)

J=

Clearance to service regulator vent outlet *(min 36"/90cm)

D= Vertical clearance to ventilated soffit located above the terminal within a horizontal

K= Clearance to non-mechanical air supply inlet to building or the combustion air inlet to

 

distance of 24"/60cm (min. 23"/58cm) (32"/81cm with vinyl siding)

 

any other appliance *(12"/30cm)

E=

Clearance to unventilated soffit (min. 23"/58cm) (32"/81cm with vinyl siding)

L=

Clearance to a mechanical air supply inlet *(min. 72"/1.8m)

F=

Clearance to outside corner: (13"/33cm)

M= Clearance above paved sidewalk or a paved driveway located on public property

G= Clearance to inside corner: (13"/33cm)

 

*(min. 84"/2.1m)

 

 

N= Clearance under veranda, porch, deck, or balcony *(min. 23"/58cm)

Note:

-A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

-Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

-If the vent termination is accessible, a certified guard shall be installed.

* As specified in CGA B149 Installation Code. Note: Local codes or regulations may require different clearances.

11

REQUIREMENTS

INSTALLATION

Page 11
Image 11
Regency P48-LP, P48-NG Requirements, Exterior, Vent terminal, Air supply outlet, Area where terminal is not permited