Regency P48-NG Horizontal Venting with Three 3 90o Elbows, Vertical Venting with Two 2 90o Elbows

Models: P48-NG P48-LP

1 48
Download 48 pages 12.3 Kb
Page 16
Image 16
Vertical Venting with Two (2) 90o Elbows

INSTALLATION

Horizontal Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

V

H

V + V1

H + H1

A)

2' Min.

1' Max.

3' Min.

4' Max.

B)

3' Min.

2' Max.

4' Min.

5' Max.

C)

4' Min.

3' Max.

6' Min.

6' Max.

D)

5' Min.

4' Max.

8' Min.

7' Max.

E)6' Min. 5 Max. 10' Min. 8' Max.

F)7' Min. 6' Max. 12' Min. 9' Max.

With these options, max. total pipe length is 30 feet with min. of 12 feet total vertical and max. 9 feet total horizontal.

Please note min. 1 foot between 90o elbows is required.

Vertical Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

V

H

V + V1

With these options, max. total

A)

1' Min.

4' Max.

2' Min.

pipe length is 30 feet with min.

B)

2' Min.

5' Max.

3' Min.

of 6 feet total vertical and max.

 

 

 

 

8 feet total horizontal.

C)3' Min. 6' Max. 4' Min. Please note min. 1 foot

D)4' Min. 7' Max. 5' Min. between 90o elbows is re-

E)5' Min. 8' Max. 6' Min. quired.

Vertical Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

H + H1

V

With these options, max. total

A)

2' Max.

2' Min.

pipe length is 30 feet with min.

B)3' Max. 3' Min. of 6 feet total vertical and max. 6 feet total horizontal.

C)4' Max. 4' Min. Please note min. 1 foot

D)

5' Max.

5' Min.

between 90o elbows is re-

E)

6' Max.

6' Min.

quired.

For additional vertical vent- ing with 2 x 90o elbows, refer to page 18.

16

Regency P48 Zero Clearance Direct Vent Gas Fireplace

Page 16
Image 16
Regency P48-NG, P48-LP Horizontal Venting with Three 3 90o Elbows, Vertical Venting with Two 2 90o Elbows, Option, H + H1