DOOR GLASS

MAINTENANCE

DOOR GLASS

Bay Glass Replacement

INSTALLING VALVE

Your Regency fireplace is supplied with high temperature 5mm-Ceramic glass. If your glass requires cleaning, we recommend using an approved glass cleaner available at all author- ized dealers. Do not use abrasive materials.

CAUTION&WARNINGS:

*Do not clean when the glass is hot.

*The use of substitute glass will void all product warranties.

*Care must be taken to avoid breakage of the glass.

*Do not strike or abuse the glass.

*Do not operate this fireplace without the glass front or with a cracked or broken glass front.

*Wear gloves when removing damaged or broken glass.

*Replacement of the glass panel(s) should be done by a licensed or qualified service per son.

1)Remove the door from the unit and place on a soft surface to prevent scratching.

2)Remove the nuts holding the glass clips in place and remove.

3)Replace the glass. The glass must have gasketing around it.

1)

Attach the valve to the valve bracket with

 

the 4 (m5x8 metric) screws provided.

2)

Reconnect the "gas out" flare fitting with an

 

11/16" wrench.

3)

Reconnect the "gas out" flare nut with a 13/

 

16" wrench.

4)

Install piezo ignitor push button assembly

 

and reconnect wire.

5)

Reconnect the quick drop out thermocouple

 

nut with a 9mm wrench.

6)

Reconnect the pilot tube nut with a 7/16"

 

wrench.

7)

Scrape off the old gasket from the floor of

 

the firebox and from the valve tray assem-

 

bly.

8)

Install a new gasket and reinstall the valve

GLASSREPLACEMENT

In the event that you break your glass by impact, purchase your replacement from an authorized Regency dealer only.

Replacement glass is shipped already installed into the door frame. Reinstall as per Glass Door Installation on page 28.

CAUTION: Wear gloves when re- moving damaged or broken glass.

WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Re- placement of the glass panels should be done by a licensed or qualified service person.

4)Reverse the previous steps, replace the glass clips and fasten with the nuts but do not over tighten, as this can break the glass.

5)Replace door on the stove and check the seal.

tray assembly.

Note: Failure to install a new gasket may severely affect the appliance performance.

9)Reinstall the 10 hold down screws.

10)Hook up the 2 TP and 2 TH wires to the appropriate connections on the valve.

11)Reinstall the two bottom deflectors and brick panels.

12)Install burner and grate assembly.

13)Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector. (Do not use open flame for leak testing.)

14)Fire up the unit temporarily.

15)Check the manifold pressure.

16)Reinstall the logs and brick panels as need- ed.

17)Close the door and replace the louvers.

18)Fire up the unit again and check for proper flame appearance and glow on logs.