Regency P48-LP Clearance to Combustibles from, Side Wall, Horizontal Vent Clearances, Mantel

Models: P48-NG P48-LP

1 48
Download 48 pages 12.3 Kb
Page 7
Image 7
CLEARANCES

INSTALLATION

CLEARANCES

The clearances listed below are Minimum distances unless otherwise stated:

A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.

Clearance to Combustibles from:

Back 0" (0mm)

Side 0" (0mm)

Floor 0" (0mm)

Caution Requirements

The top, back and sides of the fireplace are defined by standoffs. The metal ends of the standoff may NOT be

recessed into combustible construction.

Minimum Clearance from Top of Front Facing:

Mantel

min. 8"

(203mm)

Ceiling

39"

(990mm) from top of front facing above louvers.

Side Wall:

6" (152mm)

Horizontal Vent Clearances:

Top 2-1/2" (64mm)

Side 1-1/2" (38mm)

Bottom 1-1/2" (38mm)

Vertical Vent Clearances:

1-1/4" (32mm)

Alcove Clearances:

Max. Depth 36" (914mm)

Min. Width 60" (1524mm)

Min. Height 80" (2032mm)

WARNING

Fire hazard is an extreme risk

if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fireplace and vent system be installed only in

accordance with these instructions.

Heat Release Kit

The HeatWave Duct Kit and the Heat Release Kit have different clear- ance and framin require- ments, check the Heat- Wave and Heat Release manual for details.

Regency P48 Zero Clearance Direct Vent Gas Fireplace

7

Page 7
Image 7
Regency P48-LP Clearances, Clearance to Combustibles from, Minimum Clearance from Top of Front Facing, Side Wall, Mantel