Regency U32S-LP5 Installation, CONVERSION KIT # 434-969FROM NG TO LP, LP Conversion Kit Contains

Models: U32S-NG5 U32S-LP5

1 36
Download 36 pages 50.46 Kb
Page 11
Image 11
CONVERSION KIT # 434-969 FROM NG TO LP

INSTALLATION

CONVERSION KIT # 434-969 FROM NG TO LP

U32S-5 using SIT 820 NOVA Gas Valve

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER

IF IN DOUBT DO NOT DO THIS CONVERSION !!

Each Kit contains one LP Conversion Kit and one DC Sparker Kit.

LP Conversion Kit Contains:
Qty. Part #

Description

1

904-163

Burner Orifice #54

1

918-590

Decal "Converted to

 

 

LPG"

1

908-528

Red "LPG" label

1

904-529

5/32" Allen Key

1

910-037

LPG Injector

 

 

(Pilot Orifice)

1

918-480

Instruction Sheet

DC Sparker Kit Contains:

Qty. Part #

Description

1

820-475

Bracket DC Sparker

1

820-476

Bracket DC Sparker

1

904-153

Washer #8 External Star

1

904-330

Nut 8-32 Hex

1904-438 Plug Nylon 0.750 Hole, Black (for H25 only)

1904-531 Bushing Split Plastic

0.500 in.

1904-543 Screw 8-32 x 3/4 Pan Head

2904-553 Screw #8 x 1/2 Type

 

 

"B", Black Oxide

1

910-073

Spark Generator

 

 

Battery Holder

1

910-074

Spark Generator

 

 

Switch C/W Wire

1910-078 Battery Size AA Energizer En91

2910-199 Clip Wire Holder

1

910-903

Wire Fan To Power Cord

 

 

Ground 30 in.

 

904-781

Velcro Hook, Black

 

904-782

Velcro Hook, Black

1)Turn off the gas supply.

2)Remove the glass door.

a)Release the two hooks from the bottom of the glass door.

b)Swing the door out 45 degrees from the bottom and lift up and out.

3)Remove the burner by undoing the 2 screws as shown below.

Burner

4)After screws have been removed, slide the burner to the left, then lift out carefully.

5)Remove the base cover by lifting up from the back, then maneover it out.

Lift up from the back.

6)Remove burner orifice with a 1/2" wrench and discard.

Burner Orifi ce

7)Install the new LP burner orifice stamped #54 and tighten.

8)Remove the pilot shield by removing the 2 screws as shown below.

Base Cover

U32S-5 FPI Direct Vent Gas Insert

11

Page 11
Image 11
Regency U32S-LP5 Installation, CONVERSION KIT # 434-969FROM NG TO LP, U32S-5using SIT 820 NOVA Gas Valve, Qty, Description