Regency U32S-LP5, U32S-NG5 installation manual Maintenance, Replacing The Fan

Models: U32S-NG5 U32S-LP5

1 36
Download 36 pages 50.46 Kb
Page 27
Image 27
REPLACING THE FAN

MAINTENANCE

17)Remove the burner bracket.

18)Remove the Fan Air Duct by removing the 2 screws, squeeze the sides together to remove.

19)Unplug the 2 wires from the fan motor from inside the stove (located on the left side of the motor).

20)Lift Fan Assembly off of the 2 pins, tip foreward and pull through firebox opening.

21)Disconnect green ground wire from power cord.

REPLACING THE FAN

Scrape off the old gasket from the Fan Access Panel, replace and reverse above steps to replace fan

Hint: When pushing fan down onto pins - rub a dab of dishsoap on the grommet so it will slide more easily onto the pin.

Check to make sure the fan is seated properly on the pins, this is very important - try to move the fan back and forth, there shouldn't be any noise, if there is noise, check to see if the grommets have come loose.