INSTALLATION
INSTALLATION
CHECKLIST
Before installing vent system ensure that the damper plate is open and secure to prevent the damper plate from falling down and crushing the liner.
The FPI Gas Insert is installed as listed.
1)Check all clearances to combustibles, (Refer to sections "Minimum Fireplace Dimensions and Clearances to Combustibles)
2)Make the gas connection. (Refer to section "Gas Connection")
3)Install the 3" flue liner to the sliding connector plate. (Refer to section "Flue Liner Installation.")
4)Slide the unit half way into the fireplace.
5)Pull the vent connector plate through the tapered brackets and fasten to the front plate. Refer to section "Flue Liner Installation.")
6)Slide the unit fully into the fireplace.
7)Test gas pressure (Refer to section "Gas Pipe Pressure Testing"). Check aeration system (Refer to section "Gas InsertAeration System").
8)Install standard and optional features. Refer to the following sections:
a.LP Conversion Kit
b.Glass Crystals
c.Optional Ceramic Spa Stones
d.Standard Flush Door
e.Contemporary Faceplate & Door Frame f. Wall Thermostat
g. Remote Control
9)Final check: Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly. This includes:
a)Clocking the appliance to ensure the correct firing rate.
b)Adjusting the primary air, if required, to ensure that the flame does not carbon. See "Gas Insert Aeration System" section.
c)Ensuring that the appliance is venting correctly.
MANUFACTURED
MOBILE HOME
ADDITIONAL
REQUIREMENTS
1)Ensure that structural members are not cut or weakened during installation.
2)Ensure proper grounding using the #8 ground lug provided.
3)Appliance must be anchored to the floor with the supplied anchoring methods.
MATERIALS REQUIRED
No electrical power supply is required for the gas control to operate. A 120 Volt AC power cord is hooked up to the fan. Plug the 3 wire cord into a suitable receptacle. Do not cut the ground terminal off under any circumstances. When connected with 120 volts, the appliance must be electrically grounded in accordance with local codes, current version of CSAC22.1 (in Canada) or in the absence of local codes, with the National Electrical Code ANSI/NFPA
NOTE: This unit is equipped with a heat sensor thermodisc which will prevent the blower from operating until the unit reaches the correct temperature.
MINIMUM FIREPLACE
DIMENSIONS
The minimum fireplace clearances & dimensions for the FPI gas insert are shown in the following diagrams:
A
B
C
D
E
CLEARANCES TO
COMBUSTIBLES
Minimum Clearances to Combustibles
From Unit |
| |
Sides | A | 10" / 255 mm |
Ceiling | B | 47.5" / 1205 mm |
Mantel | C | 13" / 330mm |
Max. Mantle Depth | G | 12" / 305 mm |
Min. Alcove Width | K | 48" / 1220 mm |
Max. Alcove Depth | L | 36" / 915 mm |
B
G | L |
|
A
C
K
Max. Lentil | Height | Depth | Width | Width |
Bar Depth |
|
| (rear) | (front) |
A | B | C | D | E |
|
|
|
|
|
9" | 22" | 14" | ||
|
|
|
|
|
8 |