FAN MAINTENANCE

MAINTENANCE

FAN MAINTENANCE

If your fan requires maintenance or replacement, access to the fan is through the plate on the rear wall of the firebox. NOTE: the unit MUST

NOT be operated without the fan access panel securely in place.

Caution: Label all wires prior to disconnecting when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

FAN REMOVAL

1)Turn the unit off and allow it to cool down to room temperature.

2)Disconnect the power source and turn off the gas supply to the insert.

3)Open the bottom louver.

4)Remove the door frame by lifting out from the bottom and lift up off the glass door.

5)Remove the glass door.

a)Remove the 2 hooks shown below at the bottom of the glass door.

b)Swing the door out 45o from the bottom and lift up and

out.

7)Remove the burner by undoing the 2 screws shown.

a)Carefully slide the burner to the left.

b)Then lift the burner up and out carefully, ensuring not to spill the glass crystals.

Burner

Door Frame

Glass Door

U32S-5 FPI Direct Vent Gas Insert