Regency Wraps P36-LPG4, P36-NG4 45o elbows allowed, Flue must be supported at offsets, Clearances

Models: P36-NG4 P36-LPG4

1 44
Download 44 pages 50.27 Kb
Page 16
Image 16
45o elbows allowed.

INSTALLATION

The P36 is approved for a 37 ft. (11.3m) straight vertical, with Simpson Dura-Vent Co Axial Flue GS fl ue systems for LPG and NG, as per the diagram 3.

The shaded area in the diagram 3 shows all allowable combinations of straight vertical and offset to vertical terminations with Simpson Dura- Vent Co Axial Flue GS fl ue systems for LPG and NG. Maximum two

45o elbows allowed.

Flue must be supported at offsets

Firestops are required at each floor level and whenever passing through a wall.

Maintain clearances to combustibles as listed in section

"Clearances."

Diagram 3

16

Regency® P36-4 Gas Log Fireplace

Page 16