Regency Wraps P36-NG4 manual Optional Brick Panels, Log Set Installation, S.I.T. Valve Description

Models: P36-NG4 P36-LPG4

1 44
Download 44 pages 50.27 Kb
Page 21
Image 21
S.I.T. VALVE DESCRIPTION

INSTALLATION

4)Light the pilot and turn the valve to "ON" position.

5)The pressure check should be carried out with the unit burning and the setting should be within the limits specifi ed on the safety label.

6)When fi nished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" fl at screwdriver. Note: Screw should be snug, but do not over tighten.

S.I.T. VALVE DESCRIPTION

1)Gas on/off knob

2)Manual high/low adjustment

3)Pilot Adjustment

4)Thermocouple Connection - option

5)Outlet Pressure Tap

6)Inlet Pressure Tap

7)Pilot Outlet

8)Main Gas Outlet

9)Alternative TC Connection Point

OPTIONAL

BRICK PANELS

1)Undo the bottom 2 door latches and open and remove glass door. Remove logs.

Note: The logs must not be in the unit.

2)Insert the back brick panel fi rst by carefully slipping it between the back wall of the fi rebox and the rear log bracket.

3)Put the side panels in next. Slide them in from the front and push them fl at up against the wall. Be very careful not to scratch them on the fi rebox hardware.

4)Install the 2 brick retaining clips, one on each side.

LOG SET

INSTALLATION

Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.

The gas log kit (Part # 512-930) contains the following pieces:

a)02-49 Rear Log

b)02-55 Middle Left Log

c)02-50 Front Left Log

d)02-53 Center Left Log

e)02-51 Front Bottom Log

f)02-54 Center Right Log

g)02-52 Middle Right Log

h)

Embers

902-156

i)

Vermiculite

902-179

The "02" refer numbers (i.e. 02-49) are

molded into the rear of each log.

NOTE: If you will be installing the optional Brick Panels, install the Brick Panels prior to installing the logs.

1)Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position.

2)Sprinkle the vermiculite around the fi rebox base.

Vermiculite

Vermiculite

Vermiculite

3)Place the Log 02-49 on the rear log support pins with the fl at side to the back.

Regency® P36-4 Gas Log Fireplace

21