INSTALLATION

LOCATING YOUR

GAS FIREPLACE

1)When selecting a location for your stove, ensure that the clearances outlined on this page are met.

2)Provide adequate clearances for servicing.

3)The appliance must be installed on a fl at, solid, continuous surface (e.g. wood, metal, concrete).This may be the floor, or raised up on a platform to enhance its visual impact. If the appliance is going to be installed on carpeting, combustible linoleum tile or other combustible material other than wood fl ooring, the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

4)The P36 Co Axial Flue Gas Fireplace can be installed in a recessed position or framed out into the room as in A, B, C, D. See Diagram 1.

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

1)Ensure that structural members are not cut or weakened during installation.

2)Ensurepropergroundingusingthe#8ground lug provided. See section "Wiring."

CLEARANCES

The clearances listed below are Minimum distances unless otherwise stated:

A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and flue system be installed only in accordance with these instructions.

Clearance to Combustibles from:

 

Back

0"

(0mm)

Side

0"

(0mm)

Floor

0"

(0mm)

NOTE: The minimum floor clearance must be maintained from the top surface of the carpeting, tile, etc.

Minimum Clearance from Top of Unit to:

Mantel* Minimum 7" (177mm) Ceiling from top of unit. 32" (1016mm)

Side Wall Clearance

 

 

Bay or Flush Front

6"

(152mm)

Horizontal Flue Clearances

 

 

Top

2"

(51mm)

Side

1-1/2"

(38mm)

Bottom

1-1/2"

(38mm)

Vertical Flue Clearances

1-1/4" (32mm)

Alcove Clearances**:

 

 

Max. Depth

36"

(914mm)

Min. Width

48"

1219mm)

Min. Height

72"

1829mm)

* see mantle clearance instructions

(Refer to section "Combustible Mantels" & "Mantel Leg Clearances."

WARNING

Fire hazard is an

extreme risk

if these clearances are not adhered to.

Diagram 1

 

A)

Flat on Wall

 

 

B) Flat on Wall Corner

 

 

C)

Recessed into Wall/Alcove

 

 

D)

Corner

 

5)

This

appliance is Listed for bedroom

 

 

installationswhenusedwithaListedMillivolt

Clearances for Bay or Flush Front

 

Thermostat. Some areas may have further

 

 

requirements, check local codes before

 

 

installation.

 

6)

The P36 Co Axial Flue Gas Fireplace is

 

 

approved for alcove installations, which

 

 

meet the clearances listed on this page.

 

7) Werecommendthatyouplanyourinstallation on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have an authorized inspector, dealer, or installer review your plans before installation.

Note: For flue terminations see section "Exterior Flue Termination Locations."

6

Regency® P36-4 Gas Log Fireplace

Page 6
Image 6
Regency Wraps P36-LPG4, P36-NG4 Locating Your GAS Fireplace, Manufactured Mobile Home Additional Requirements, Clearances

P36-NG4, P36-LPG4 specifications

Regency Wraps has made a significant mark in the world of grill accessories with its high-quality products, particularly the P36-LPG4 and P36-NG4 wraps. These wraps are designed specifically for grill enthusiasts who value durability, functionality, and aesthetic appeal in their cooking equipment.

The P36-LPG4 model is tailored for those who prefer liquid propane as their fuel source. It boasts a robust construction that ensures longevity and resilience against the elements. One of the key features of the P36-LPG4 is its heat-resistant fabric, which is crafted to withstand high temperatures without compromising the integrity of the wrap. This makes it an ideal choice for situations where intense heat is a norm, providing both safety and performance.

On the other hand, the P36-NG4 model caters to natural gas users. Similar to its LPG counterpart, the P36-NG4 is engineered to handle the rigors of outdoor grilling while offering a stylish appearance. The wrap is designed to fit a range of traditional grills, ensuring a snug yet flexible fit that protects the grill from dust, debris, and harsh weather conditions.

Both models feature advanced technologies, including UV resistance, which helps in maintaining the vibrant colors and quality of the fabric over time. This is crucial for outdoor gear that often faces prolonged exposure to the sun, preserving the product's aesthetic charm as well as its functional attributes.

The characteristics of the P36-LPG4 and P36-NG4 wraps extend beyond mere protection. They are equipped with user-friendly features such as easy installation; most users can simply slip the wrap over their grill in seconds. The wraps are also lightweight, which enhances portability for grillers who like to take their equipment on the go.

Furthermore, both wraps are designed with ease of maintenance in mind. They can be cleaned effortlessly, ensuring that grill enthusiasts can maintain their equipment in pristine condition without excessive effort or time.

In summary, Regency Wraps offers the P36-LPG4 and P36-NG4 models as the ultimate solution for grill protection, combining style with superior functionality. With their durable construction, advanced technologies, and user-friendly design, these wraps are a worthy investment for any grilling aficionado looking to enhance their outdoor cooking experience.