GOLD-PLATED &

MAINTENANCE

3)Check for evidences of excessive condensation,suchaswaterdropletsforming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fi ttings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather.

4)Inspect joints, to verify that no pipe sections or fi ttings have been disturbed, and consequently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.

GOLD-PLATED &

BRASS

LOUVRES OR TRIM

The 24 carat gold plated or brass fi nish on the trim requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the finish and void the warranty.

Clean any fingerprints off before turning the unit on. If the top louvres start to discolour, check the door gasket seal and replace if necessary.

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door and carefully remove the logs. (The pilot light generates enough heat to burn someone.) If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagrams under Log Installation.

Note: Improper positioning of logs may create carbon build-up and will severely alter the unit's performance which is not covered under warranty.

THERMOPILE /

THERMOCOUPLE

1)Open the bottom louvres.

2)Loosen the thermocouple or thermopile with a 7/16" spanner.

3)Disconnect thermocouple by loosening nut from the valve with a 9mm spanner. Disconnect thermopile by loosening 2 screws marked TP on the valve.

4)Drop the thermocouple or thermopile down from the bracket and pull it out of the unit.

5)Reinstall the new ones in reverse order.

GLASS GASKET

If the glass gasket requires replacement use 5/8" fl at glass gasket for the Bay Front (Part

#936-243) and a tadpole glass gasket for the Flush Front (Part # 936-155).

DOOR GLASS

Your Regency® fi replace is supplied with high temperature,5mmNeoceramceramicglassthat will withstand the highest heat that your unit will produce. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materials. Do not clean the glass when hot.

In the event that you break your glass by impact, purchase your replacement from an authorized Regency® dealer only, and follow our step-by- step instructions for replacement.

WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or qualified service person.

Caution: Wear gloves when removing damaged or broken glass.

Flush Glass Replacement

Remove the fl ush door front (as per instructions in section "Standard Flush Door"). Remove the 4 glass clips from each corner. Slide in the new replacement glass. Push the 4 glass clips back onto the frame. The glass must have gasketing around it.

Bay Glass Replacement

1)Remove the door from the unit and place on a soft surface to prevent scratching.

2)Remove the nuts holding the glass clips in place and remove.

3)Replace the glass. The glass must have gasketing around it.

5)Reversetheprevioussteps,replacetheglass clips and fasten with the nuts but do not over tighten, as this can break the glass.

6)Replace door on the stove and check the seal.