Regency Wraps P36-LPG4, P36-NG4 Copy Of The Lighting Plate Instructions, Maintenance Instructions

Models: P36-NG4 P36-LPG4

1 44
Download 44 pages 50.27 Kb
Page 32
Image 32
COPY OF THE LIGHTING PLATE INSTRUCTIONS

OPERATING INSTRUCTIONS

COPY OF THE LIGHTING PLATE INSTRUCTIONS

FORYOURSAFETYREADBEFORELIGHTING

This appliance must be installed in accordance with local codes, if any; if not, follow the current CAN1-B149/ANSI Z 223.1 (Australia: AS5601-2004, New Zealand: NZS 5261)

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss oflife.Improperinstallation,adjustment,alteration,serviceormaintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or gas supplier.

MAINTENANCE

INSTRUCTIONS

1) Alwaysturnoffthegasvalvebeforecleaning.

For relighting, refer to lighting instructions.

Keep the burner and control compartment

clean by brushing and vacuuming at least

once a year. When cleaning the logs, use a

soft clean paint brush as the logs are fragile

and easily damaged.

2) Clean appliance and door with a damp

cloth (never when unit is hot). Never use

an abrasive cleaner. The glass should be

cleaned with a gas fi replace glass cleaner.

The glass should be cleaned when it

A)This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B)BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

-Do not try to light any appliance

-Do not touch any electric switch, do not use any phone in your building

-Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s instructions.

-If you cannot reach your gas supplier, call the fire department.

C)Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D)Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

starts looking cloudy.

3) The heater is fi nished in a heat resistant

paint and should only be refinished with heat

resistant paint. Regency® uses StoveBright

Paint - Metallic Black #6309.

4) Make a periodic check of burner for proper

position and condition. Visually check the

flame of the burner periodically, making sure

the fl ames are steady; not lifting or fl oating.

If there is a problem, call an authorized

service person.

5) The appliance and fl ueing system must be

inspected before use, and at least annually,

by an authorized fi eld service person, to

ensure that the fl ow of combustion and

ventilation air is not obstructed.

CAUTION:Hotwhileinoperation.Donottouch.SevereBurnsmayresult.Due to high surface temperatures keep children, clothing and furniture, gasoline and other liquids having fammable vapors away. Keep burner and control compartment clean. See installation and operating instructions

accompanying appliance.

LIGHTINGINSTRUCTIONS

STOP! Read the safety information above on this label.

1)Push in gas control knob slightly and turn to “PILOT” position.

2)Push in control knob all the way and hold in until the pilot lights up. Continue to hold the control knob in for about 20 seconds after the pilot is lit. Release knob.

3) Push in gas control knob slightly and

Gas Inlet

turn to "ON" position.

4) Turn ON the flame switch.

TO TURN OFF GAS APPLIANCE

You may shut off the pilot during prolonged non use periods to conserve fuel.

1)Turn OFF the flame switch.

2)Push in gas control knob slightly and turn to "OFF" position.

DO NOT REMOVE THIS INSTRUCTION PLATE

918-253a

Note: Never operate the appliance without the glass properly secured in place.

6)Donotusethisapplianceifanyparthasbeen under water. Immediately call an authorized service technician to inspect the appliance and to replace nay part of the control system and any gas control which has been under water.

7)Verify operation after servicing.

General Flue Maintenance

Conduct an inspection of the fl ueing system semi-annually. Recommended areas to inspect as follows:

1)Check the Flueing System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These components should be replaced immediately.

2)Remove the Cap, and shine a fl ashlight down the Flue. Remove any bird nests, or other foreign material.

32