Remington QFP40 manual Conversion Instructions, Cont, Lp Conversion

Models: QFP40

1 68
Download 68 pages 34.69 Kb
Page 15
Image 15
CONVERSION INSTRUCTIONS, (CONT.)

REMINGTON QFP40 Direct Vent FIREPLACE

CONVERSION INSTRUCTIONS, (CONT.)

Burner Orifice Replacement

5.If logset is installed, remove logs and embers at this time.

6.Use a Phillips screwdriver to remove pilot lighting channel and front log rack.

7.Remove the two Phillips head screws that secure the front and rear burner pans in place.

8.Remove the burner pans by sliding to the right and lifting out. (Shutters may need to be adjusted ‘closed’ to make this easier).

9.Slide shutters out of the way. Using a 3/8" wrench or socket, remove the orifice inserts and replace with proper orifices for the specified gas. See below.

10.Reinstall burner pans and adjust shutters to ‘open’ position.

NOTE: THe right phillips screw holding front and rear burners in place should be left slightly loose to allow for expansion.

CAUTION: The correct orifice placement is critical for proper appliance performance .

 

Natural Gas

Propane

Main Burner Orifice Front (DMS)

#47

#56

Main Burner Orifice Rear (DMS)

#42

#53

Note: Logs and burners will be reinstalled following pilot orifice replacement.

Pilot Orifice Replacement:

13.Lift pilot hood and remove. See Fig. A

14.Remove existing pilot orifice with a 5/32” allen wrench. See Fig. B

15.Replace pilot orifice with the correct orifice for your gas type as follows:

LP = .016 NG = .025

FIG. B

FIG. A

11.Replace pilot hood: Ensure that the notches are aligned and snap hood into place.

12.Reinstall Log Rack, pilot lighting channel, burners, lava rock and logs.

13.Install LP conversion label inside the apliance beneath the firebox, to the left of the control panel.

LP CONVERSION

250-4721 JUNE 2001