REMINGTON QFP40 Direct Vent FIREPLACE

HORIZONTAL INSTALLATION (CONT.)

Step 5. Slide the stove and vent assembly (see Fig. 9 below) towards the wall, carefully inserting the vent pipe into the vent cap assembly. It is important that the vent pipe extend into the vent cap sufficient distance so as to result in a minimum pipe overlap of 1¼" (32mm). Secure the connection between the vent pipe and the vent cap by attaching the two sheet metal strips extending from the vent cap assembly into the outer wall of the vent pipe. Use the two sheet metal screws provided to connect the strips to the pipe section. (Figure 9).

Note: The attachment from the vent pipe to the vent cap must be siliconed. Venting terminals shall not be recessed into a wall or siding.

FIG. 9

FOLD STRAP HERE

SHEET METAL SCREW

WALL THIMBLE/CEILING

FIRESTOP AS REQUIRED BY

LOCAL JURISDICTION.

STRAP

250-4721 JUNE 2001

VENTING