BLOWER REPLACEMENT

MAINTENANCE

REMINGTON QFP40 Direct Vent FIREPLACE

BLOWER REPLACEMENT

Part #842-3790

1.Disconnect power to unit at power supply (this may require shutting off power at the circuit breaker box).

2.Remove fascia and door.

3.Remove control panel cover.

4.Disconnect white wire from white wire at junction box in unit.

5.Disconnect black wire from snap disc.

NOTE: Removing the blower requires passing the blower unit through a restricted area. Care must be taken to ensure that your gas line is out of the way. Depending on your gas line installation, it may be necessary to discon- nect your gas line on the valve side of shutoff within the unit and move the flex line aside.

6.Reach in and take hold of one or both ends of the blower impeller(s) and lift it up off mounting studs.

7.Pull blower forward, towards the back of valve.

8.Slide blower all the way to your right.

9.Rotate left side of blower towards the front of unit.

10.Carefully maneuver blower out the front, over gas line between control panel and door latch.

11.Reinstall new blower in reverse order.

NOTE: When reinstalling ensure that rubber grommets on the end being inserted first are not dislodged from the blower.