TROUBLSHOOTING

TROUBLSHOOTING

REMINGTON QFP40 Direct Vent FIREPLACE

TROUBLESHOOTING

Pilot won’t light

Is a gas shut-off valve turned on?

Is the valve control knob turned to “PILOT” (See Lighting Instructions, #7, Pg. 55).

Is the valve control knob pushed in? (See Lighting Instructions, #8)

Was the igniter pressed repeatedly? (See Lighting Instructions, #8)

Main Burners Will Not Start

Has the pilot light gone out? (See Lighting Instructions, Pg. 55).

Is the gas control valve turned to “PILOT” or “OFF” ? (See Lighting Instructions).

Is the ON/OFF switch in the “OFF” position? (Turn to “ON”)

Is the remote control working correctly?

(See instruction manual for the remote control).

Is the thermostat disconnected or set too low? (See Thermostat Operation, Pg. 47).

If LP, is the tank empty?

Remote Control Does Not Turn Unit On / Off

Has the pilot light gone out? (See Lighting Instructions, Pg. 55).

Is the gas control valve turned to “PILOT” or “OFF? (See Lighting Instructions).

Is the ON/OFF switch turned to “OFF”? (Turn the switch to “OFF”)

If the switch is on, unit will remain on.

Is the remote too far away from the fireplace? (Use remote closer to fireplace)

Is the remote control receiver turned “OFF”?

(See instruction manual for the remote control).

Are the remote control batteries dead?

(See instruction manual for the remote control).

Thermostat Does Not Work

Has the pilot light gone out? (SeeLighting Instructions, Pg. 55).

Is the gas control valve turned to “PILOT” or “OFF” ? (See Lighting Instructions).

Is the thermostat set too low? (See Thermostat Operation, Pg. 47).

Is the On/OFF switch turned to “OFF? (Set the switch to “ON”)

If switch is on, unit will remain on. (The switch overrides the thermostat.)

Fireplace Will Not Distribute Heat

Is the fireplace getting electricity? (Check the breaker switch)

Is the fireplace up to temperature? (See Operating Procedures, Pgs. 54-58).

Is Blower operational? (Check Fan Speed control, Pg. 58).