REMINGTON QFP40 Direct Vent FIREPLACE

TROUBLESHOOTING, (CONT.)

Pilot Goes Out Once a Month or More

Has the gas supply been shut off? (Keep gas supply turned on)

Flames Are Too blue

Has the fireplace just been started? (This is normal - see Initial Start-up Pg. 54).

Primary Air adjustment--contact dealer.

Flames Are Too Short (Under 6”)

Is the flame height may be turned too low? (Turn the flame height to “HI”; see Adjusting the Flame Height, Pg. 56).

Primary air adjustment - Contact Dealer.

Damper adjusted properly? - Contact Dealer.

Thin Layer of Soot Covers the Glass

Are the logs or embers placed incorrectly? (See Log Set Installation, Pg. 50).

Is the air shutter adjusted properly? (Contact Dealer for Air Shutter adjustment)

Damper adjusted properly?

Fireplace Design:

Many of the components within this fireplace are designed specifically for safety purposes. It is therefore imperative that only certified gas service technicians should service this fireplace.

Main Burner Operation:

A millivolt system controls the operation of this fireplace. The thermopile and thermocouple generate electricity when heated by the pilot flame. This electricity is used to operate the gas valve. Without enough electricity, the gas valve will not turn on. That is why when starting the pilot the gas control knob has to be pressed in long enough for the thermocouple to heat up and generate enough electricity. The thermopile provides power for the ON/OFF switch, remote control, or thermostat. Because the thermopile generates the electricity needed to turn the fireplace on and off, this fireplace can be operated when the power is out (although the blower will not run).

Gas Buildup Prevention Feature:

This appliance’s utilization of a high-technology gas valve in conjunction with a pilot flame ensures that no gas builds up inside the firebox.

The thermocouple (next to the pilot) senses when the pilot flame is lit. If the pilot flames goes out, this thermocouple no longer generates electricity, causing the gas valve to automatically shut off all gas to the heater, preventing the pilot from spilling gas into the firebox.