Remington QFP40 manual How To Use Vent Graph, Venting

Models: QFP40

1 68
Download 68 pages 34.69 Kb
Page 32
Image 32
HOW TO USE VENT GRAPH

VENTING

REMINGTON QFP40 Direct Vent FIREPLACE

HOW TO USE VENT GRAPH

1.Measure the distance from the top of stove to the center of the 90° elbow. On the graph below, draw a horizontal line from that measurement on the vertical axis across until it intersects with the slanted line.

2.From the point of this intersection, draw a vertical line to the bottom of the graph.

3.The point at which this line meets the bottom line of the graph is the maximum length of the horizontal run.

Example 1: If the vertical dimension from the top of the stove to the center of the 90° elbow is 7' (2.13m), the horizontal run to the outer wall flange must not exceed 9' 9" (2.97m).

Example 2: If the vertical dimension from the top of the stove is 21’ (6.4m), the hori- zontal run to the outer wall flange must not exceed 7’ 3" (2.21m).

Note: The maximum horizontal vent run is 15' (4.57m) when the vertical vent rise is 10' (3.05m).

The minimum horizontal vent run is 12" (305mm).

Minimum wall thickness is 4" (102mm). Maximum wall thickness is 20" (508mm).

Vent damper may need to be adjusted if your installation falls in the shaded area shown in graph.

Ex. 2

VERTICAL DISTANCE FROM APPLIANCE TOP TO THE 90° ELBOW

EX. 1

30'

 

 

 

 

 

 

 

 

 

28'

 

 

 

 

 

 

 

 

 

26'

 

 

 

 

 

 

 

 

 

24'

 

 

 

 

 

 

 

 

 

22'

 

 

 

 

 

 

 

 

 

20'

 

 

 

 

 

 

 

 

 

18'

 

 

 

 

 

 

 

 

 

16'

 

 

 

 

 

 

 

 

 

14'

 

 

 

 

 

 

 

 

 

12'

 

 

 

 

 

 

 

 

 

10'

 

 

 

 

 

 

 

 

 

8'

 

 

 

 

 

 

 

 

 

6'

 

 

 

 

 

 

 

 

 

4'

 

 

 

 

 

 

 

 

 

2'

 

 

 

 

 

 

 

 

 

0'

11"

2'

4'

6'

8'

10'

12'

14'

15'

 

 

(MIN)

 

 

 

 

 

 

 

(MAX)

TOTAL HORIZONTAL RUN TO OUTSIDE OF EXTERIOR WALL (EXCLUDING ELBOWS)

Page 32

250-4721 JUNE 2001

Page 32
Image 32
Remington QFP40 manual How To Use Vent Graph, Venting