REMINGTON QFP40 Direct Vent FIREPLACE

Step 4.

VENTING

NOTE:

 

 

(1)

 

(2)

Page 36

HORIZONTAL INSTALLATION (CONT.)

Position the horizontal vent termination in the center of the 10" (254mm) square hole, run a bead of non-hardening mastic around its outside edges, so as to make a seal between it and the wall, attach termination cap to the exterior wall with the four wood screws provided. The arrow on the vent cap should be pointing up (Figure 7) . Insure that proper clearances to combustible materials are maintained.

WOOD SCREW

FIG. 7

HOT

 

 

 

 

 

 

 

 

 

 

 

PART #985 OR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HHW2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.

If you are using Simpson DuraVent termination cap # 985 on a building with vinyl siding, a vinyl siding standoff (Simpson Dura-Vent Part #950), should be installed between the vent cap and the exterior wall (Figure 8). Attach the vinyl siding standoff to the horizontal vent termination. The vinyl siding standoff prevents excessive heat from possibly melting the vinyl siding material. Vent terminal shall not be recessed into a wall or siding. Remove siding from beneath area of standoff.

VINYL SIDING

APPLY SEALANT

ALL FOUR SIDES

FIG. 8

SCREWS

BOLT HORIZONTAL TOP

TO VINYL STANDOFF

VINYL SIDING STANDOFF w/

SIDING BENEATH REMOVED

250-4721 JUNE 2001

Page 36
Image 36
Remington QFP40 manual Wood Screw, HHW2, Siding Beneath Removed