SAVING PROGRAMS

29C040 512K [1-3], [2-4]

To change the EPRO M in U6, remove the IC and replace it with the new one. Whe n installing a 29C256, pin 1 on the IC goes into socket pin 3. The top two rows of pins are empty.

ALTERNATE EPROMS

Flash EPR OMs ar e more expensive than UV er asable or OTPs as of this writing. Large volume OEM' s may wish to use lower cost EPRO Ms.

Program development must use flash EPROM s. Whe n a program is finished, the flash EP ROM is used as a master. Use an exter nal progra m to duplicate progr ams.

Jumper W2 is normally configured for flash EPROM (W2[3-5 ] and W2 [4-6]). For non-flash E PRO Ms, W2 is configured for [1 - 3] and [2- 4]. Large volume OEM's should contact Remote Processing regarding pre- configuring W2 and W3 for your application.

SECTION 3

COMMANDS

The following is a list of RPBASIC-52 commands used for saving, loading, and executing programs and data. These comm ands and functions are explained in the Software Supplement in this manua l.

Comm and

Function

BLOAD

Transfers binary data from

 

EPROM to RAM

BSAVE

Transfers binary data from RAM

 

to flash EPROM

EXECUTE

Loads, clear s memory, then runs

 

a program from w ithin a program

LOAD n

Loads a program from EPROM

SAVE n

Saves a program to flash EPROM

Page 3-3 RPC -320

Page 14