R61509V | Target Spec |
Notes to RGB Interface Operation
1. The following functions are not available in RGB interface operation.
Table 64 Functions Not Available in RGB Interface operation
Function | RGB Interface | Internal Display Operation |
Partial display | Not available | Available |
Scroll function | Not available | Available |
2.The VSYNCX, HSYNCX, and DOTCLK signals must be supplied during display period.
3.The reference clock to generate liquid crystal panel controlling signals in RGB interface operation is DOTCLK, not the internal clock generated from the internal oscillator.
4.When switching between the internal operation mode and the external display interface operation mode, follow the sequences below in setting instruction.
5.In RGB interface operation, front porch period continues after the end of frame period until next VSYNCX input is detected.
6.RGB and
7.In RGB interface operation, RAM address
Internal Clock Operation to RGB Interface (1) | RGB Interface (1) to Internal Clock Operation |
Internal clock operation
AM = 0
RAM address set
Set
Display operation in synchronization with internal clocks
*Instruction setting for
the RGB interface operation
is enebled from the next frame period.
RGB interface operation
Set internal clock operation mode*
Wait one frame period or more
Display operation in synchronization with VSYNCX, HSYNCX, and
DOTCLK
*Instruction setting to the internal clock operation is enebled from the next frame period.
Display operation in synchronization with
Set index register to R202h
Wait one frame period or more
Write data to RAM via RGB interface
Internal clock operation | internal clocks |
Note: Continue RGB interface signals at least for one frame period after setting
Display operation in synchronization with VSYNCX, HSYNCX, and DOTCLK
Operation via RGB interface
Note: Input the RGB interface signals before setting the
Figure 49 RGB and Internal Clock Operation Mode Switching Sequences
Rev. 0.11 April 25, 2008, page 128 of 181