Renesas R61509V manual Display Control 3 R009h

Models: R61509V

1 181
Download 181 pages 26.85 Kb
Page 48
Image 48

R61509V

 

 

 

 

 

 

 

 

 

 

 

 

 

Target Spec

 

Display Control 3 (R009h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R/W

RS

IB15

IB14

IB13

IB12

IB11

IB10

IB9

IB8

IB7

IB6

IB5

IB4

IB3

IB2

IB1

IB0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R/W

1

0

0

0

0

PTV

PTS

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PTS: Sets the source output level to drive non-display area. PTS also selects operation of grayscale amplifier and step-up clock frequency.

Table 15

 

 

Source output in non-lit display area (Note)

Grayscale amplifier

Non-lit display area

PTS

 

Step-up clock frequency

 

 

 

 

 

 

in operation

 

Positive polarity

Negative polarity

 

 

 

 

 

 

 

 

 

 

0

V63

V0

 

V0 to V63

Register setting (DC0, DC1)

 

 

 

 

 

 

1

V63

V0

 

V0, V63

Register setting (DC0) x 1/2

Note: The power efficiency improved by halting grayscale amplifiers and slowing down the step-up clock frequency can be obtained in non-display drive period.

PTV: Sets the VCOM output in non-lit display area. When PTV=1, frame inversion in non-lit display area is selected.

Table 16

PTV

VCOM operation in non-lit display drive period

0BC setting

1Frame inversion