268106r1.book Page 22 Thursday, November 30, 2006 2:35 PM

CPAP mode

S mode

VSet mode

(First screens only display if Ramp or Settling are selected)

Mode/Ramping Indicator

 

 

 

Mode/Ramping Indicator

Mode/Settling Indicator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Set) EPAP pressure

 

EPAP

 

 

CPAP pressure

 

 

 

 

 

 

 

 

 

 

 

(Set) IPAP pressure

 

 

 

IPAP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C:RAMP

8.0

 

 

 

 

S:RAMP

8.0

 

 

 

 

 

 

VS:SETL

8.0-11.0

 

 

 

 

-11.0

 

 

 

 

A>

 

exit

 

 

 

 

 

S>>>>

 

PS 3.0

A>>>>

 

 

PS 3.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure Support

 

 

 

 

 

 

 

 

 

 

Mode

 

 

 

 

 

 

 

 

 

 

(Set) PS

CPAP

15.0

 

SPONT:

8.0-11.0

 

 

 

 

VSET

8.0-11.0

 

 

A>>>

 

exit

 

 

 

 

S>>>>

 

PS 3.0

A>>>>

 

PS 3.0

 

 

 

 

 

 

 

 

 

 

 

 

Trigger Indicator

 

 

 

 

 

 

 

 

 

 

Apnea Indicator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure Graph

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Apnea Indicator

Leak

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Respiratory rate (bpm)

 

 

LK: 24L/min

RR: 12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minute ventilation (L/min)

 

 

MV: 12.0

 

VT:1000

 

 

 

Tidal volume (mL)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Breath/phase/expiration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Top row: VSet and S mode only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S**TiMn

TiMx 4.0

 

Ti Max setting (sec)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Average inspiration time

 

 

Ti 2.1s

 

1: 1.6

 

 

 

 

Average I:E ratio (last 5 breaths)

 

 

 

 

 

(last 5 breaths)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Oxygen saturation (%)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(This screen only displays if ResLink

 

 

 

 

 

SpO2 : 12%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heart rate (BPM)

 

 

 

HR : 57

 

 

exit

and an oximeter are connected)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: (Set) values are those selected by the clinician.

The treatment screens contain the following information:

Treatment mode: Mode of treatment set by your clinician. Options are: CPAP, S and VSet.

Ramping indicator: (CPAP mode, S mode) Appears if the VPAP Malibu is in ramp mode. This disappears once the ramp time has elapsed.

Settling indicator: (VSet mode) Appears if the VPAP Malibu is in settling mode. This disappears once the settling time has elapsed.

Set pressure(s): In CPAP mode, this displays the set treatment pressure (centimeters of water). In S mode, it displays exhalation and inhalation pressures (centimeters of water). In VSet mode, it displays the AutoSet pressure (mean mid-point pressure between inhalation and exhalation).

Trigger indicator: (S mode) How the VPAP Malibu changes the pressure when you are inhaling. "S" (Spontaneous) indicates a patient triggered change. Apnea indicator: (CPAP mode, VSet mode) Visual indicator that displays an "A" to indicate an apnea is occurring.

Pressure bar graph: Graphical display of the changing pressure.

Leak: Current mask leak (liters per minute).

Respiratory rate: Number of breaths per minute.

22

Page 27
Image 27
ResMed C16389 dimensions Cpap mode Mode, VSet mode