Service Program Mode
Fax Maintenance
RX Settings
RX Settings
Silence Detection Time
CNG Tone Detection Time
CNG Cycles
Tone Sound
Monitoring
Stop/Clear key
Silence (No tone) detection time (Rx mode : FAX/ TAD Only)
After the line is connected via the external telephone, the machine can detect silence (no tone) for the time length specified by this setting.
[30 sec (Default)]
CNG tone detection time ( RX mode : FAX / TEL, FAX / TAD Only)
After the line is connected via the external telephone, the machine can detect a CNG signal for the time length specified by this setting.
[5 Sec (Default)/ 10 Sec]
Number of CNG cycles to be detected
This setting is only effective for FAX/TAD mode. [1.5 Cycle (Default)/ 2.0 Cycle]
Determines the period when tones from the line are monitored.
[No Monitoring/ Up To Phase B (Default)/ All TX Phases]
Pressing the Stop/Clear key can stop the current receiving operation. Received data is lost.
[Not Functional (Default)/ Functional]
Sets the
[10V (Default)/ 15V/ 20V/ 25V 35V]
"Telephone" was indicated by malfunction when receiving the fax message with some PABX. Some PABX may output more than 25V to the FAX input line. Selecting [35V] for
5
99