Service Program Mode
Fax Maintenance
V34 Settings
Equalizer
Redialing
First TX Speed
Symbol Rate
These selectors set the equalizer's training level to be applied if training fails due to poor line connection.
[Automatic (Default)/ 4 Points/ 16 Points]
Resend when a communication error occurs. [Disabled (Default)/ Not Disabled]
Sets the first transmission speed choice, before fallback. [2400 Bps/ 4800 Bps/ 7200 Bps/ 9600 Bps
/12000 Bps/ 14400 Bps/ 16800 Bps/ 19200 Bps/
21600 Bps/ 24000 Bps/ 26400 Bps/ 28800 Bps/
31200 Bps/ 33600 Bps (Default)]
This setting limits the transmission speed range in V.34 mode by masking the desired symbol rate(s).
[Not Used (Default)/ 3429 Sym/Sec
/3200 Sym/Sec/ 3000 Sym/Sec
/2800 Sym/Sec/ 2400 Sym/Sec]
5
Factory Default
Factory Default
Not Execute
Execute
Does not execute anything. Returns to an upper level.
Resets all the settings to factory default.
•Clears/ resets the contents of the controller board memory (all data programmed by the user, log data) to factory default.
After executing, initial setup menu starts after
CTL Maintenance
CTL Maintenance | PDL Mode | ON = "PDL Settings" is shown (Default) | ||||
OFF = "PDL Settings" is hidden | ||||||
|
|
|
| |||
|
|
|
|
|
|
103