Ricoh 406460 SC 4xx Image Transfer and Transfer Error, SC 5xx Motor and Fusing Error

Models: 406460

1 162
Download 162 pages 36.99 Kb
Page 121
Image 121

Service Call Conditions

SC 4xx (Image Transfer and Transfer Error)

Bias leak

An error signal is detected for 0.2 seconds when changing the development unit.

491

 

 

Defective transfer roller

 

 

 

 

 

 

Defective high voltage power pack

 

 

1.

Turn the machine's main power off, and then on.

 

 

 

 

 

SC 5xx (Motor and Fusing Error)

Main motor error

The machine does not detect a main motor lock signal within 2sec after the main motor started to rotate.

-or-

The machine does not release a main motor lock signal within 2sec after the main motor switched off.

-or-

The machine detects a main motor lock signal every 100ms for seven times consecutively, after

500the main motor started to rotate stably.

Overload of

Torque load overload

Defective main motor

Disconnect or defective motor harness

6

530

1.Turn the machine's main power off, and then on.

2.Check or replace the main motor if the torque load is normal.

3.Replace the motor harness.

Fusing Fan Motor Error

The FAN lock signal – High for 10 seconds, after the fan motor started to rotate.

• Disconnected or defective motor harness.

1. Turn the machine's main power off, and then on.

119