4. Replacement and Adjustment

Reinstallation

Pass the cable [A] of fusing unit through the hole [B] outside, after setting the fusing unit.

4

After installing a new fusing unit

1.Enter the "Maintenance Mode".

2.Select "Engine Maintenance", and then press "OK" key.

3.Select "Reset Fusing Unit Life" and then press "OK" key.

4.Select "Execute" and then press "OK" key.

Thermostat

Do not recycle a thermoswitch that is already opened. Safety is not guaranteed if you do this.

1. Fusing unit [A] ( x 3)

2. Fusing upper cover [A] ( x 4)

66