System Settings

Parallel Interface

This section describes the user tools in the Parallel Interface menu under Interface Settings.

Default settings are shown in bold type.

2

Parallel Timing

Sets the timing for the control signal of the parallel interface.

The default setting is ACK Outside.

Parallel Communication Speed

Sets the communication speed for the parallel interface. The default setting is High Speed.

Selection Signal Status

Sets the level for the select signal of the parallel interface. The default setting is High.

Input Prime

Sets whether to validate or invalidate the input prime signal upon receipt. The default setting is Inactive.

Bidirectional Communication

Sets the printer's response mode to a status acquisition request when using a parallel interface.

The default setting is On.

When set to [Off], bidirectional communication function will be disabled. Al- so, printer driver will not be installed under Windows Auto Detect function.

Signal Control

Sets procedure to error during printing.

The default setting is Job Acceptance Priority.

52